SWRCB,January 2002 Page q of t <br /> 7. UNDER-DISPENSER CONTAINMENT UDC TESTING <br /> Test Method Developed By: 0 UDC Manufacturer 0 Industry Standard ❑Professional Engineer <br /> X Other(Spec) Incon <br /> Test Method Used: ❑Pressure ❑Vacuum X Hydrostatic <br /> Other(Spec) <br /> Test Equipment Used: Incon TS-STS Sump Test System Equipment Resolution: 0.002 <br /> MINEENNIONNOM <br /> UDC#9A UDC#9/10A UDC#10/I1A UDC# 11/12A <br /> UDC Manufacturer: Bravo Bravo Bravo Bravo <br /> UDC Material: Steel Steel Steel Steel <br /> UDC Depth: 12" 12" 12" 12" <br /> Height from UDC Bottom to Top <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to Dirty Dirty Dirty Dirty <br /> testing: <br /> Portion of UDC Tested' 1/3 1/3 1/3 1/3 <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both 1 0 Yes ❑No X NA 0 Yes 0 No X NA ❑Yes 0 No X NA ❑Yes ❑No X NA <br /> product and water)?* <br /> Turbine shutdown response time N/A N/A N/A N/A <br /> Is system programmed for fail- 0 Yes ❑No X NA 0 Yes 0 No X NA ❑Yes 0 No X NA ❑Yes ❑No X NA <br /> safe shutdown?* <br /> Was fail-safe verified to be 0 Yes 0 No X NA 0 Yes ❑No X NA 0 Yes 0 No X NA 0 Yes 0 No X NA <br /> operational?* <br /> Wait time between applying 5 min 5 min 5 min 5 min <br /> pressure/vacuum/water and <br /> starting test <br /> Test Start Time: 11:19 11;19 11:19 1:05 <br /> Initial Reading(RI): 0.1613 0.7970 0.0904 0.2301 <br /> Test End Time: 11:34 11:34 11:34 1:20 <br /> Final Reading(RF): 0.1604 0.7966 0.0901 0.2300 <br /> Test Duration: 15 min 15 min 15 min 15 min <br /> Change in Reading(RF-Ri): 0.0009 0.0004 0.0003 0.0001 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> y <br /> Test Result , <a :X Pass ❑F`aiY = X Pass, ,q,FaYIC.Pass„ CIa�l R= as a� , .� ,r <br /> Was sensor removed for testing? ❑ Yes ❑No X NA ❑ Yes ❑No X NA ❑ Yes ❑No X NA ❑ Yes ❑No X NA <br /> Was sensor properly replaced and ❑ Yes ❑No X NA ❑ Yes ❑No X NA ❑ Yes 0 No X NA ❑ Yes 0 No X NA <br /> verified functional after testin ? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for ailed tests) <br /> ii <br /> FA MEMO <br /> 2015 <br /> _, <br /> 'If the entire depth of the UDC is not tested,specify how much was tested. If the answer to My of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />