My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0009270
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TOSTE
>
2450
>
3500 - Local Oversight Program
>
PR0545734
>
ARCHIVED REPORTS_XR0009270
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2020 2:06:08 PM
Creation date
6/5/2020 1:37:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0009270
RECORD_ID
PR0545734
PE
3528
FACILITY_ID
FA0010191
FACILITY_NAME
TRACY-PONTIAC-CADILLAC-GMC TRUCK
STREET_NUMBER
2450
STREET_NAME
TOSTE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
238020-06
CURRENT_STATUS
02
SITE_LOCATION
2450 TOSTE RD
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> E18 September 1998 <br /> • AGE-NC Project No 96-0254 <br /> EPage 4 of 8 <br /> E Monitoring wells MW-3 (Boring B11), MW-5 (Boring B13) and MW-6 (Boring B12) were <br /> completed with 0 02-inch slotted screen from depths of 5 to 15 feet bsg A filter pack was <br /> installed using #3 Lonestar sand from 3 to 15 feet Bentonite chips were used to make a 2- <br /> foot plug above the sand filter packs The remaining annular space was backfilled to the <br /> surface with portland cement A traffic-rated well box(8-Inch diameter) was Installed over <br /> each well, in accordance with County regulations <br /> I <br /> As-built monitoring well diagrams for each monitoring well are Included as Appendix B <br /> I <br /> 2 5 MONITORING WELL SURVEY <br /> E The casing elevations of each well Installed for the Curtiss-Pontiac UST investigation were surveyed <br /> g y <br /> relative to MW-I located at 2420 Grant Line Road (Grant Line Gas and Food) Well MW-1 at 2420 <br /> EGrant Line Road was previously surveyed with a relative elevation of 20 feet above mean sea level <br /> Combining the two sites in a survey will allow the use of wells from 2420 Grant Line Road site to <br /> lie be used in the calculation of the gradient and ground water flow direction for the Curtiss-Pontiac site <br /> E2 6 GROUND WATER DEPTH MEASUREMENT AND PURGING <br /> On 27 February 1998, a Sollnst water level meter was used to measure the depth to ground water in <br /> E each well relative to the top of the well casings After ground water depth measurements were <br /> collected, each monitoring well was purged using a two-stage submersible pump Approximately <br /> 10 gallons of water(a minimum of 3 well volumes per well)were evacuated from MW-1 A, MW-2A, <br /> E MW-3, MW-5 and MW-6, approximately 15 gallons of water were purged from MW-1 B and MW- <br /> 2B <br /> ETemperature,pH and conductivity of were measured at 2-gallon intervals in wells MW-1 A,MW-2A, <br /> MW-3, MW-5 and MW-6, and at 3-gallon intervals In wells MW-1B and MW-2B Ground water <br /> E parameters were collected using an lCM model 52200 water analyzer Field logs of the <br /> measurements are included in Appendix C Purged water was temporarily stored on-site in 55-gallon <br /> drums <br /> E <br /> 27 COLLECTION AND ANALYSIS OF GROUND WATER SAMPLES <br /> EWater samples were collected from each monitoring well using a disposable bailers The samples <br /> • were transferred into 40-m1 EPA-approved vials containing 0 5 ml of hydrochloric acid (18%) as a <br /> Advanced GeoEnvi ron mental Inc <br /> E <br />
The URL can be used to link to this page
Your browser does not support the video tag.