My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
3105
>
2231-2238 – Tiered Permitting Program
>
PR0506982
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2021 11:16:58 AM
Creation date
6/5/2020 2:18:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2231-2238 – Tiered Permitting Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0506982
PE
2231
FACILITY_ID
FA0003680
FACILITY_NAME
CALIFORNIA TANK LINES INC
STREET_NUMBER
3105
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
17512028
CURRENT_STATUS
01
SITE_LOCATION
3105 S EL DORADO ST
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
209
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Tank Assessment Page Tank Name: Final Neutralizer Tanks <br />Tank ages: Purchased new, used 20 years <br />Remainina service life: Estimated 5 years. <br />Tank Construction: <br />Shape: Cylindrical, flat bottom, open top. <br />Orientation. Vertical. <br />Location: Above Ground, inside building (no sun exposure). <br />Material of Construction: High Density Crosslinked Polyethylene <br />Thickness: 0.228" 'fk. 1, 0.249" 'I'k. 2, 0.182" Tk. 3, measured 6" below the top, <br />using an ultrasonic gage. <br />Lining material and thickness: NA <br />Corrosion protection equipment: NA <br />Other identifying features: Seamless, One Piece Construction, Natural, <br />rotationally molded. <br />Piping and ancillary equipment (pumps): <br />Piping Material of Construction: Poly Vinyl Chloride (PVC). <br />Piping Diameter: 3 in_ <br />Pump location: in pre -neutralizer area. <br />Pump type/capacity: centrifugal pump - 40 gpm <br />Pipe from the pre -neutralizer pump to the final neutralizer tank, 26 R. long, is <br />entirely within the secondary containment arca, and is hydrostatically tested at 6 <br />psi semi-annually. <br />Material Storage: <br />Materials and characteristics: Wastewater with pH between 7 and 10. <br />Specific Gravity: approx_ 1 <br />Operating Capacity: 370 gallons. <br />Chemical compatibility findings: The materials identified above: are compatible for <br />contact with or proximity to the equipment, tank or tank system in this assessment. <br />Initials: 0-, � <br />Visual l nspection : <br />Tank parameters at time of inspection: in use. <br />Acute visual evidence of leaks: none. <br />Condition of interior surface: good. <br />Condition of exterior surface: good_ <br />Condition. of nozzles, flanges, fittings at tank: good_ <br />Condition of piping: good. <br />Visual Inspection findings: A visual inspection of the tanks and affiliated piping and <br />ancillary equipment did not reveal signs of leaks, corrosion, weld cracks or breaks, or <br />scrapes in protective coating which may cause a release from the tank system. A <br />description of all discrepancies noted during the visual ilaspection is included with this <br />report. Initials: <br />California Tank Lines, Inc. Final Neutralizer'l'anks (3) <br />
The URL can be used to link to this page
Your browser does not support the video tag.