UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM(Page s of s) <br /> Xll. LINE LEAK DETECTOR TESTING <br /> ❑Check this box if line leak detectors(LLD)are NOT installed (Do not complete this section.) Y N NA <br /> This section must be completed if LLDs are installed. <br /> Was a leak simulated to verify LLD performance? ❑ ❑ ❑ <br /> (Check all that apply) Simulated leak rate verified ❑X 3 GPH ❑ 0.1 GPH ❑0 2 GPH <br /> Was the testing apparatus property calibrated? ❑x ❑ ❑ <br /> For emergency generator tank systems,does the LLD create an audible and visual alarm when a teak is detected? ❑ ❑ Q <br /> For mechanical LLDs,does the LLD restrict the flow through the pipe when a leak is detected? ❑ ❑ ❑X <br /> For electronic LLDs,does the turbine automatically shut off when a leak is detected? X ❑ I ❑ <br /> For electronic LLDs,does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ❑X _❑ I ❑ <br /> For electronic LLDs,does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? ❑X ❑ I CD— <br /> For <br /> For electronic LLDs,have all accessible wiring connections been visually inspected for kinks and breaks? ❑X ❑ ❑ <br /> Were all items on the equipment manufacturer's maintenance checklist completed? X ❑ ❑ <br /> Were all LLDs confirmed operational within regulatory requirements? X ❑ ❑ <br /> For any answer of"N"above,describe in Section X111 how and when these issues were or will be corrected. <br /> XIII. COMMENTS <br /> XIV. VACUUM/PRESSURE/HYDROSTATIC MONITORING EQUIPMENT TESTING <br /> X Check this box if VPH monitoring is NOT used. (Do not complete this section) <br /> This section must be completed if VPH monitoring is used to perform leak detection monitoring. <br /> System Type(Mark all that apply) ❑X Vacuum ❑Pressure ❑X Hydrostatic <br /> Sensor ID Component(S)Monitored By This Sensor Sensor Functionality tnterstilial Communication <br /> Test Test <br /> 7 97 Prud•__1 ❑X Pass ❑Fail ❑X Pass ❑Fail <br /> 9 97 Vern X❑Pass ❑Fail ❑X Pass ❑Fail- <br /> 10 <br /> ad10 Vapor U•cs ❑X Pass ❑Fail Q Pass ❑Fail- <br /> 11 <br /> ad11 91 Pruduc" ❑X Pass ❑FailX❑Pass ❑Fail <br /> 12 91 Vent ❑X Pass ❑Fail ❑X Pass ❑Fail <br /> 13 DSL.Produce ❑X Pass ❑Fail ❑X Pass ❑Fail <br /> 14 DSL Vent ❑X Pass ❑Fail ❑X Pass ❑Fail <br /> L1 Di;p 112 ❑X Pass ❑Fail ❑X Pass ❑Fail <br /> L2 Disp 314 ❑X Pass ❑Fail Q Pass ❑Fall <br /> L3 Disp 5 G ❑X Pass ❑Fail ❑X Pass ❑Fail <br /> L4 Disp 7 B ❑X Pass ❑Fail ❑X Pass ❑Fail <br /> L5 e7 SIP ❑X Pass ❑Fail ❑X Pass ❑Fail <br /> How was interstitial communication verified? ❑X Simulated Leak at Far Ends of the Interstitial Space ❑X Visual Inspection ' <br /> ❑Other(Describe the method in section XV below) ❑Gauge <br /> Was the vacuum or pressure restored to operating levels in all interstitial spaces? ❑X Yes ❑No(Describe the reason in section XV below) <br /> For any answer of"Fail"above,describe in Section XV how and when these issues were or will be corrected. <br /> XV. COMMENTS <br /> Replaced S12 91 Vent Vac Sensor <br /> GPH=Gallons Per Hour,Y=Yes N=No NA=Not Applicable VPH=Vacu u ,PressureJHydrostatrc,ID=Ident licati_-rt <br />