My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2001-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
2320
>
2300 - Underground Storage Tank Program
>
PR0231084
>
COMPLIANCE INFO_2001-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2024 4:10:21 PM
Creation date
6/23/2020 6:41:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2011
RECORD_ID
PR0231084
PE
2361
FACILITY_ID
FA0006447
FACILITY_NAME
SHELL FOOD MART
STREET_NUMBER
2320
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12521030
CURRENT_STATUS
01
SITE_LOCATION
2320 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\E\EL DORADO\2320\PR0231084\FINAL JUDGMENT 11-06-09.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
507
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />SWRCB, January 2002 Page q of <br />6. PIEPING SUMP TESTING <br />Test Method Developed By: ❑ Sump Manufacturer ❑ Industry Standard X Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum X Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Caldwell Level Change Indicator <br />Equipment Resolution: .002 <br />Sump # I Sump # 2 <br />Sump # 3 Sump # <br />Sump Diameter: 48" 48" <br />48" <br />Sump Depth: 55 %" <br />54 %:" <br />55" <br />Sump Material: Fiberglass <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top of Product 16" <br />Product 16 %:" <br />Product 16" <br />Highest Pi in Penetration: <br />Height from Tank Top to Lowest 13" <br />16'/x" <br />14" <br />Electrical Penetration: <br />Condition of sump prior to testing: Dry <br />Dry <br />Dry <br />Portion of Sump Tested' Water Line 20" <br />Water Line 20" <br />Water Line 20" <br />Does turbine shut down when <br />sump sensor detects liquid (both X Yes ❑ No (INA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />product and water)?* <br />Turbine shutdown response time Not Alarmed <br />Not Alarmed <br />Not Alarmed <br />Is system programmed for fail-safe X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No 0 NA <br />❑ Yes ❑ No ❑ NA <br />shutdown?` <br />Was fail-safe verified to be Yes X No ❑ NA <br />Yes X No ❑ NA <br />Yes X No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />o erational?` <br />Wait time between applying water 10 Minutes <br />10 Minutes <br />10 Minutes <br />and starting test: <br />Test Start Time: 10:05 <br />9:55 <br />10:45 <br />Initial Reading (RI): .001 <br />.001 <br />.001 <br />Test End Time: 10:35 <br />10:25 <br />11:15 <br />Final Reading (RF): .001 <br />.001 <br />.001 <br />Test Duration. 30 Minutes <br />30 Minutes <br />30 Minutes <br />Change in Reading (RF -RI): 0 <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: .005/30 Minutes <br />.005/30 Minutes <br />.005/30 Minutes <br />Test Result: X Pass ❑ Fail <br />X Pass ❑ Fail <br />X Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Was sensor removed for testing? X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />verified functional after testing? <br />Comments —(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.