Laserfiche WebLink
' If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />SWRCB, January 2002 Page q of <br />6. PIEPING SUMP TESTING <br />Test Method Developed By: ❑ Sump Manufacturer ❑ Industry Standard X Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum X Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Caldwell Level Change Indicator <br />Equipment Resolution: .002 <br />Sump # I Sump # 2 <br />Sump # 3 Sump # <br />Sump Diameter: 48" 48" <br />48" <br />Sump Depth: 55 %" <br />54 %:" <br />55" <br />Sump Material: Fiberglass <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top of Product 16" <br />Product 16 %:" <br />Product 16" <br />Highest Pi in Penetration: <br />Height from Tank Top to Lowest 13" <br />16'/x" <br />14" <br />Electrical Penetration: <br />Condition of sump prior to testing: Dry <br />Dry <br />Dry <br />Portion of Sump Tested' Water Line 20" <br />Water Line 20" <br />Water Line 20" <br />Does turbine shut down when <br />sump sensor detects liquid (both X Yes ❑ No (INA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />product and water)?* <br />Turbine shutdown response time Not Alarmed <br />Not Alarmed <br />Not Alarmed <br />Is system programmed for fail-safe X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No 0 NA <br />❑ Yes ❑ No ❑ NA <br />shutdown?` <br />Was fail-safe verified to be Yes X No ❑ NA <br />Yes X No ❑ NA <br />Yes X No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />o erational?` <br />Wait time between applying water 10 Minutes <br />10 Minutes <br />10 Minutes <br />and starting test: <br />Test Start Time: 10:05 <br />9:55 <br />10:45 <br />Initial Reading (RI): .001 <br />.001 <br />.001 <br />Test End Time: 10:35 <br />10:25 <br />11:15 <br />Final Reading (RF): .001 <br />.001 <br />.001 <br />Test Duration. 30 Minutes <br />30 Minutes <br />30 Minutes <br />Change in Reading (RF -RI): 0 <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: .005/30 Minutes <br />.005/30 Minutes <br />.005/30 Minutes <br />Test Result: X Pass ❑ Fail <br />X Pass ❑ Fail <br />X Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Was sensor removed for testing? X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />verified functional after testing? <br />Comments —(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />