1 � <br /> 0. Alter ce construction for new underground storage tanks containing motor vehicles fuel [Section 26333. <br /> (1) Monitoring and response plan [Section 26341. <br /> (2) Underground storage tank composed of.... <br /> (a) Fiberglass reinforced plastic. <br /> (b) Cathodicalty protected steel. <br /> (c) Steel clad with fiberglass reinforced plastic. <br /> (d) Other material that complies with section 2631 and 2632. <br /> f (3.) Floor of teak interception and detection system constructed on a firm base and stoped to a <br /> collection sump (use of membrane liners comply with section 2631 (d) (6) requirements.) <br /> (4) Access casings installed in the collection sumo of the secondary containment system with <br /> backfill in the interstitial space. The access casing shall meet all of the following: <br /> Designed and installed to allow the Liquid to flow into the casing- <br /> Sized to allow removal of collected liquid and able to withstand all anticipated applied <br /> stresses. <br /> Constructed of material that will not be structurally weakened. <br /> Screened along entire vertical zone of permeable material. <br /> Capable of preventing leakage of any hazardous substance from the casing. <br /> Extend to the ground surface and covered with a Locked waterproof cap. <br /> Capable of meeting S.J. Co. PHS-i-:40 '.lett Standards. <br /> Leak interception and detection system shall prevent the leaked hazardous substance from <br /> entering around water. <br /> 14. INTERSTITIAL SPACE MONITORING <br /> A. Visual monitoring [Section 2632 (c) (1)] <br /> (a) Exterior surface and floor beneath tank monitored by direct viewing <br /> (b) Daily visual inspections <br /> (c) Liquid level in tank to be recorded at time of inspection <br /> (d) If liquid observed around or beneath primary tank, owner will determine if an unauthorized release <br /> has occurred. <br /> 3. Mechanical or electronic monitoring [Section 2632 (c) (2)I <br /> (a) Continuous monitoring system connected to an audible and visual alarm system. <br /> Moniitoring equipment to be installed <br /> Manufacturer..\/ <br /> Model Number- <br /> Sensor Type: _ Vapor .11, Liquid 3oth. <br /> Sensor/Pant s <br /> .� pecifications. <br /> Locations) for sensors: y <br /> Tank. T1A-(1 Piping: `�Ll <br /> 0ispen sar: p 5 <br /> C. Monitoring and response plan submitted [Section 2632 (d) (1) 4 (2)i. <br /> 15. Any special accessories, fittings, coatings, or linings not inherent within the initial design of the 10 tank or <br /> double-wall UST. [Section 2631 (b)1 <br /> A. Approved by a nationally recognized independent testing organization. <br /> 3. Demonstration of integrity with the primary and/or secondary containment. <br /> 6 <br />