My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
1901
>
2300 - Underground Storage Tank Program
>
PR0231092
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2020 4:19:40 PM
Creation date
6/23/2020 6:41:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231092
PE
2361
FACILITY_ID
FA0001946
FACILITY_NAME
El Dorado Food Mart
STREET_NUMBER
1901
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16508019
CURRENT_STATUS
01
SITE_LOCATION
1901 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231092_1901 S EL DORADO_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
321
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
v/ <br />Page 5 of 9 .�. <br />Test Method Developed By: ❑ UDC Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Level Change Indicator <br />Equipment Resolution: 0.0025 <br />UDC # 1-2 <br />UDC # 3-4 <br />UDC # <br />UDC # <br />UDC Manufacturer: <br />Unknown <br />Unknown <br />UDC Material: <br />Fiberglass <br />Fiberglass <br />UDC Depth: <br />28 in <br />28 in <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />9 in <br />9 in <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />7 in <br />7 in <br />Condition of UDC prior to <br />testing: <br />Dry <br />Dry <br />Portion of UDC Tested' <br />2° above prod. piping <br />2" above prod. piping <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)? <br />❑Yes ❑No ®NA <br />[-]Yes [—]No ®NA <br />Turbine shutdown response time <br />* See comments <br />* See comments <br />Is system programmed for fail- <br />safe shutdown?. <br />❑Yes [-]No❑NA <br />❑Yes [-]No ®NA <br />Was fail-safe verified to be <br />operational?* <br />❑Yes [:]No ®NA <br />❑Yes ❑No ®NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />5 min <br />5 min <br />Test Start Time: <br />12:55 PM <br />1:00 PM <br />Initial Reading (R,): <br />0 <br />0 <br />Test End Time: <br />1:25 PM <br />1:30 PM <br />Final Reading (RF): <br />0 <br />4 <br />Test Duration: <br />30 min <br />30 min <br />Change in Reading (RF -R,): <br />0 <br />4 <br />Pass/Fail Threshold or Criteria: <br />0.0025 <br />0.0025 <br />Test Result: <br />[Z Pass ' ❑ Fail <br />❑ Pass ® Fail <br />❑ Pass ❑ Pail <br />❑ Pass ❑ Fail <br />Was sensor removed for testing? <br />®Yes ❑No ❑NA <br />®Yes [:]No [:INA <br />❑Yes ❑No ❑NA <br />❑Yes ❑No ❑NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />®Yes [:]No ❑NA <br />®Yes ❑No ❑NA <br />❑Yes [-]No DNA <br />Dyes ❑No DNA <br />Comments — (include information on repairs made prior to testing, and recommended, follow-up for failed tests) <br />* UDC sensor(s) were tested separately as part of the annual monitor certification test. <br />UDC 3-4 failed due to a confirm leak from the top UDC wall electrical penetration. A troubleshooting test under the <br />top electrical penetration was performed with passing result. Signs of past repairs could be identified. Need to repair <br />and retest the UDC. Please see the enclosed picture. <br />�'a,ra1 �°o�t��rs°PR��AsT <br />If the entire depth of the UDC is not tested, specify how much was tested. If the answer to an\, of the questions indicated with an <br />asterisk(*) is "NO" or "NA". the entire UDC must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.