Laserfiche WebLink
r <br />Bravo CONV=B2000 <br />Dispenser Conversion Frame <br />Water Splash for new dispenser <br />prevents water intrusion. <br />Typically 3/4" minimum height. <br />Raises dispenser 2" to <br />clear sump water splash <br />lip of existing UDC. <br />Height may be greater <br />than 2" depending on <br />application. <br />Angled plates to direct any <br />leaks from hydraulic cabinet <br />back into the existing UDC. <br />Structural supports for existing <br />concrete anchor bolts to secure <br />conversion frame to island / <br />pad. Bolt points vary based on <br />dispenser and range from 2-8. <br />Alternate / additional <br />structural supports <br />for new concrete <br />anchor bolts <br />New Dispenser <br />Anchor Bolt point. <br />These vary in number: <br />2-6 bolt points. <br />(bolts are included <br />but not installed) <br />> Tailored exactly to the old dispenser, the new <br />Included <br />dispenser and the existing UDC below <br />Components <br />> Island/concrete & dispenser anchor mounting <br />for Dispensor <br />points with deep -socket ratchet access <br />anchoring: <br />> Integrated water splash lip & drainage panels <br />> Galvannealed & epoxy powder coated <br />8x Hex bolts <br />> Rugged & reinforced 12ga steel construction <br />8x zinc nuts <br />> 1/2" anchor bolts & frame caps included <br />8x zinc washers <br />8x plastic plugs <br />Third Party <br />E <br />Approved ,, <br />3 ii-CONV-B2000-Conversion Frame -14A - 8/20/2014 <br />