Laserfiche WebLink
A& a� V�9 <br />• ` Manufacturer. -4 a Model: <br />18. PIPING INFORMATION <br />PIPING INFORMATION <br />TANK# <br />TANK# <br />TANK# <br />TANK# <br />DISTANCE from <br />DISPENSER to TANK <br />0 <br />, <br />7C? <br />MANUFACTURER <br />®0• <br />SYSTEM TYPE * <br />E <br />CONSTRUCTION ** <br />'D c -L3 <br />MATERIAL *** <br />6Z`P <br />VP <br />FR, <br />LEAK DETECTION <br />SYSTEM <br />r r L <br />C <br />100% COMPATIBILITY <br />WITH METHANOL <br />c '`� <br />e c- <br />Cy� <br />CORROSION <br />PROTECTION <br />* System Type; suction, pressure, and gravity <br />** Construction: single -walled, double -walled, lined -trench, etc. <br />*** Material Type; steel with cathodic protection, stainless-steel, fiberglass reinforced plastic. <br />19. Piping (cross-sectional diagram, including connections to tank and dispensers). <br />(A) Vent and tank riser primary containment system equipped with overfill prevention system that: <br />Restricts delivery of flow to tank [Section 2635 (b) (2) (B) or (C)], or <br />Provide positive shut off of flow to the tank at no more than 95 % [Section 2635 (b)(2)(C)], or <br />(B) Vapor recovery piping designed so it cannot contain liquid phase product, or <br />(C) Suction piping (below grade piping operates at less than atmospheric pressure) [Section 2636 (a) (3)] <br />Sloped so contents of the pipe will drain back into the storage tank if the suction is released. <br />No valves or pumps installed below grade. <br />Inspection method provided to demonstrate compliance with section 2636 (a) (3). <br />(D) Corrodible underground piping protected against corrosion (Section 2636 (b)). <br />(E) Underground primary piping will meet all of the following requirements <br />Primary piping in contact with hazardous substance under normal operation conditions shall be: <br />installed inside a secondary containment system in the form of: secondary pipe Vault or <br />lined trench to be sloped to a collection sump at the low point of the piping. <br />Primary piping and secondary containment systems will be installed in accordance with industry <br />code of practice and voluntary consensus standards.. <br />Lined trench used as secondary containment <br />Material compatible with the substance stored. <br />Covered and capable of supporting any expected vehicular traffic. <br />(F) Underground piping with secondary containment will be equipped and monitored as follows: <br />Secondary containment will be equipped with a continuous monitoring system connected to an <br />audible and visual alarm system. <br />N <br />