My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DE VRIES
>
13850
>
2300 - Underground Storage Tank Program
>
PR0231547
>
COMPLIANCE INFO_2008-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2023 3:48:09 PM
Creation date
6/23/2020 6:49:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2018
RECORD_ID
PR0231547
PE
2361
FACILITY_ID
FA0003848
FACILITY_NAME
Verizon Business: KINGCA
STREET_NUMBER
13850
Direction
N
STREET_NAME
DE VRIES
STREET_TYPE
RD
City
LODI
Zip
95240
APN
05524018
CURRENT_STATUS
01
SITE_LOCATION
13850 N DE VRIES RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231547_13850 N DE VRIES_2008-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
582
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to = of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />Page 5 of 8 <br />7. UNDER -DISPENSER CONTAINMENT QDC ) TESTING <br />Test Method Developed By: <br />U UDC Manufacturer U Industry Standard U Professional Engineer <br />U Other (Specify) <br />Test Method Used: <br />U Pressure U Vacuum <br />U Hydrostatic <br />13 Other (Specify) <br />Test Equipment Used: Equipment Resolution: <br />UDC # UDC <br />UDC <br />UDC Manufacturer <br />777 <br />UDC Material: <br />UDC Depth: <br />Height from UDC Bottom to Top of <br />Highest Pip!M Penetration: <br />Height from UDC Bottom to Lowest <br />Electrical Penetration: <br />Condition of UDC 'or to testing: <br />Portion of UDC Tested' <br />Does turbine shut down when UDC <br />sensori liquid (both product <br />U Yes Q No Q NA Q Yes U No U NA U Yes U No UNA <br />Q Yes Q No 0 NA <br />and waterV <br />Turbine shutdown response time <br />Is system programmed for fail-safe <br />U Yes Q No 0 NA Q Yes U No 0 NA U Yes 13 No U NA <br />Q Yes Q No U NA <br />shutdown7 <br />Was fail-safe verified to be <br />13 Yes Q No 13 NA Q Yes C) No Q NA G Yes 0 No 0 NA <br />0 Yes Q No Q NA <br />OREEgM47 <br />Wait time between applying <br />pressurelvacuum/water and staffing <br />test <br />Test Start Time: <br />Initial Reading (R): <br />Test End Time: <br />Final Reading (RF): <br />Test Duration: <br />Change in Reading (RF -R): <br />Pass/Fall Threshold or Criteria: <br />Test Result: <br />0 Pass Q Fail 0 Pass Q Fail Q Pass 13 Fail <br />0 Pass Q Fail <br />Was sensor removed for testing? <br />U Yes Q No Q NA Q Yes U No Q NA U Yes 0 No Q NA <br />U Yes U NO Q NA <br />Was sensor properly replaced after <br />U Yes Q No 0 NA 0 Yes Q No Q NA 0 Yes LINO Q NA <br />C11 Yes Q No Q NA <br />testing? <br />Comments - (include inform abn on <br />Man� n&mL* grfEto liesdm, and recommended follow-up for tailed tests) <br />No UDC <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to = of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />