My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DE VRIES
>
13850
>
2300 - Underground Storage Tank Program
>
PR0231547
>
COMPLIANCE INFO_2008-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2023 3:48:09 PM
Creation date
6/23/2020 6:49:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2018
RECORD_ID
PR0231547
PE
2361
FACILITY_ID
FA0003848
FACILITY_NAME
Verizon Business: KINGCA
STREET_NUMBER
13850
Direction
N
STREET_NAME
DE VRIES
STREET_TYPE
RD
City
LODI
Zip
95240
APN
05524018
CURRENT_STATUS
01
SITE_LOCATION
13850 N DE VRIES RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231547_13850 N DE VRIES_2008-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
582
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
P }�.H A G i £3.A & <br />z <br />S <br />6. PIPING SUMP TESTING <br />Page 4 <br />Test Method Developed By: <br />❑ Sump Manufacturer X Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: <br />❑ Pressure <br />❑ Vacuum <br />X Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Ronan/Caldwell Hydrostatic Sump Tester <br />Equipment Resolution: 0.0000" <br />Sump # 1 <br />Sump # Vent Tran <br />Sump # Pipe Tran <br />Sump # <br />Sump Diameter: <br />42" <br />— 30" x 20" <br />— 30" x 20" <br />Sump Depth: <br />— 48" <br />—3011 <br />— 30" <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top of <br />Hi est Pip!Rg Penetration: <br />— 12" <br />—2419 <br />— 24" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />— 24" <br />— 24" <br />NA <br />Condition of sump prior to testing: <br />Good <br />Good <br />Good <br />Portion of Sump Tested' <br />— 24" <br />— 24" <br />— 24" <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />❑ Yes ❑ No X NA <br />❑ Yes ❑ No X NA <br />❑ Yes ❑ No X NA ❑ Yes <br />❑ No 0 NA <br />roduct and water)?* <br />Turbine shutdown response time <br />NA <br />NA <br />NA <br />Is system programmed for fail-safe <br />shutdown?` <br />0 Yes 0 No X NA <br />❑ Yes ❑ No X NA <br />❑ Yes ❑ No X NA ❑ Yes <br />❑ No 0 NA <br />Was fail-safe verified to be <br />-operational?* <br />❑ Yes D No X NA <br />0 Yes ❑ No X NA <br />0 Yes ❑ No X NA ❑ Yes <br />0 No 0 NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />+/- 30 Min <br />+/- 30 Min <br />+/- 30 Min <br />test: <br />Test Start Time: <br />12:00 PM <br />12:00 PM <br />12:00 PM <br />Initial Reading (RI): <br />- <br />- <br />- <br />Test End Time: <br />12:00 PM <br />12:00 PM <br />12:00 PM <br />Final Reading (RF): <br />- <br />- <br />- <br />Test Duration: <br />24 hr <br />24 hr <br />24 hr <br />Change in Reading (RF -RI): <br />No Loss <br />No Loss <br />No Loss <br />Pass/Fail Threshold or Criteria: <br />PASS = <br />No Loss or Loss of 0.0020" or less in 12 minutes <br />Was sensor removed for testing? <br />X Yes ❑ No ❑ NA <br />X Yes 0 No ❑ NA <br />X Yes 0 No DNA <br />❑ Yes <br />0 No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testin ? <br />X Yes 0 No DNA <br />X Yes 0 No DNA <br />X Yes D No DNA <br />❑ Yes <br />0 No 0 NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up }or failed tests) <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to my of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />I:\apps\JOBS\2006\1493\SB989.doc <br />