Laserfiche WebLink
t!t:z <br />C o; r, <br />� - <br />6_ PiPTN[s' CiTMP TF..TTN(: ® '1 o In <br />Test Method Developed By: ❑ Sump MAnufacturer ® Industry Standard ❑ Professro al Engineer <br />❑ Other (Spec) ENVIRONN,IENTAL HEALTH <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydro _ ET/SER=E <br />❑ Other (Spec) <br />Test Equipment Used: INCON - TS -STS Equipment Resolution: 0.0001 <br />Sump # 87 Sump # 91 Sump # DSL Sump # <br />Sump Diameter: 36" 36" 37" <br />Sump Depth: 73" <br />70" <br />51" <br />Sump Material: FG <br />FG <br />FG <br />Height from Tank Top to Top of 39" <br />39" <br />18" <br />Highest Piping Penetration: <br />Height from Tank Top to Lowest 21" <br />19" <br />11" <br />Electrical Penetration: <br />Condition of sump prior to testing: FAIR <br />FAIR <br />FAIR <br />Portion of Sump Tested' 44" <br />44" <br />23" <br />Does turbine shut down when <br />sump sensor detects liquid (both ® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />product and water)?* <br />Turbine shutdown response time 6 SEC <br />6 SEC <br />6 SEC <br />Is system programmed for fail-safe ® Yes ❑ No ❑ NA <br />shutdown?' <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />Was fail-safe verified to be <br />®Yes [INo [INA <br />®Yes ❑ No ❑ NA <br />®Yes ❑ No [:]NA ❑Yes ❑ No ❑ NA <br />operational?* <br />Wait time between applying <br />pressure/vacuum/water and starting 15 MIN <br />15 MIN <br />15 MIN <br />test: <br />Test Start Time: 10:30 <br />10:30 <br />12:00 <br />Initial Reading (Ri): 3.0048 <br />3.1223 <br />2.6838 <br />Test End Time: 10:45 <br />10:45 <br />12:15 <br />Final Reading (RF): 3.0046 <br />3.1222 <br />2.6838 <br />Test Duration: 15 MIN <br />15 MIN <br />15 MIN <br />Change in Reading (RF--Rr): 0.0002 <br />0.0001 <br />0 <br />Pass/Fail Threshold or Criteria: 0.002 <br />0.002 <br />0.002 <br />Test Re$ult: pass. ;:: ❑ Fail. <br />_. <br />M Pais _ ❑ FBiI <br />'BSS;; ❑Fail ❑.PSSS ❑Fall <br />Was sensor removed for testing? ® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />®Yes ❑ No ❑ NA <br />®Yes ❑ No ❑ NA <br />®Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA <br />verified functional after testin ? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to ly of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />Secondary Containment Test Results 4 of 7 <br />