My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
880
>
2300 - Underground Storage Tank Program
>
PR0231746
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2024 2:40:14 PM
Creation date
6/23/2020 6:51:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231746
PE
2361
FACILITY_ID
FA0003862
FACILITY_NAME
Marks Fuel & Food, Inc.
STREET_NUMBER
880
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
049-050-32
CURRENT_STATUS
01
SITE_LOCATION
880 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231746_880 E VICTOR_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
441
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t!t:z <br />C o; r, <br />� - <br />6_ PiPTN[s' CiTMP TF..TTN(: ® '1 o In <br />Test Method Developed By: ❑ Sump MAnufacturer ® Industry Standard ❑ Professro al Engineer <br />❑ Other (Spec) ENVIRONN,IENTAL HEALTH <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydro _ ET/SER=E <br />❑ Other (Spec) <br />Test Equipment Used: INCON - TS -STS Equipment Resolution: 0.0001 <br />Sump # 87 Sump # 91 Sump # DSL Sump # <br />Sump Diameter: 36" 36" 37" <br />Sump Depth: 73" <br />70" <br />51" <br />Sump Material: FG <br />FG <br />FG <br />Height from Tank Top to Top of 39" <br />39" <br />18" <br />Highest Piping Penetration: <br />Height from Tank Top to Lowest 21" <br />19" <br />11" <br />Electrical Penetration: <br />Condition of sump prior to testing: FAIR <br />FAIR <br />FAIR <br />Portion of Sump Tested' 44" <br />44" <br />23" <br />Does turbine shut down when <br />sump sensor detects liquid (both ® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />product and water)?* <br />Turbine shutdown response time 6 SEC <br />6 SEC <br />6 SEC <br />Is system programmed for fail-safe ® Yes ❑ No ❑ NA <br />shutdown?' <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />Was fail-safe verified to be <br />®Yes [INo [INA <br />®Yes ❑ No ❑ NA <br />®Yes ❑ No [:]NA ❑Yes ❑ No ❑ NA <br />operational?* <br />Wait time between applying <br />pressure/vacuum/water and starting 15 MIN <br />15 MIN <br />15 MIN <br />test: <br />Test Start Time: 10:30 <br />10:30 <br />12:00 <br />Initial Reading (Ri): 3.0048 <br />3.1223 <br />2.6838 <br />Test End Time: 10:45 <br />10:45 <br />12:15 <br />Final Reading (RF): 3.0046 <br />3.1222 <br />2.6838 <br />Test Duration: 15 MIN <br />15 MIN <br />15 MIN <br />Change in Reading (RF--Rr): 0.0002 <br />0.0001 <br />0 <br />Pass/Fail Threshold or Criteria: 0.002 <br />0.002 <br />0.002 <br />Test Re$ult: pass. ;:: ❑ Fail. <br />_. <br />M Pais _ ❑ FBiI <br />'BSS;; ❑Fail ❑.PSSS ❑Fall <br />Was sensor removed for testing? ® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />®Yes ❑ No ❑ NA <br />®Yes ❑ No ❑ NA <br />®Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA <br />verified functional after testin ? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to ly of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />Secondary Containment Test Results 4 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.