COMPLIANCE INFO_2012-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
880
>
2300 - Underground Storage Tank Program
>
PR0231746
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2024 2:40:14 PM
Creation date
6/23/2020 6:51:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231746
PE
2361
FACILITY_ID
FA0003862
FACILITY_NAME
Marks Fuel & Food, Inc.
STREET_NUMBER
880
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
049-050-32
CURRENT_STATUS
01
SITE_LOCATION
880 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231746_880 E VICTOR_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
441
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
n <br />E <br />79 Y1► E- 1 * <br />Test Method Developed By: <br />' <br />❑ UDC Manufacturer ® Industry Standard ❑ Professie <br />IR <br />El Other (Spec)' <br />Test Method Used: <br />❑ Pressure <br />❑ Vacuum <br />® HY ME TAL HEALTH <br />❑ Other (Spec) <br />PERMIT/SERVICES <br />Test Equipment Used: INCON TS -STS <br />Equipment Resolution: 0.0001 <br />UDC # 1/2 <br />UDC # 3/4 <br />UDC # 5/6 <br />UDC # 7/8 <br />UDC Manufacturer: <br />UNKNOWN <br />UNKNOWN <br />UNKNOWN <br />UNKNOWN <br />UDC Material: <br />FG <br />FG <br />FG <br />FG <br />UDC Depth: <br />27" <br />27" <br />27" <br />27" <br />Height from UDC Bottom to Top <br />10" <br />10" <br />9" <br />10" <br />of Highest Piping Penetration: <br />Height from UDC Bottom to <br />10" <br />10" <br />9" <br />10" <br />Lowest Electrical Penetration: <br />Condition of UDC or to <br />FAIR <br />FAIR <br />FAIR <br />FAIR <br />testing: <br />Portion of UDC Tested' <br />15" <br />15" <br />14" <br />14" <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />product and water)?* <br />Turbine shutdown response time <br />6 SEC <br />6 SEC <br />6 SEC <br />6 SEC <br />Is system programmed for fail- <br />® Yes ® No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />safe shutdown?* <br />Was fail-safe verified to be <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />o erational?* <br />Wait time between applying <br />pressure/vacuum/water and <br />15 MIN <br />15 MIN <br />15 MIN <br />15 MIN <br />starting test <br />Test Start Time: <br />12:30 <br />12:30 <br />1:30 <br />1:30 <br />Initial Reading (RI): <br />2.7832 <br />1.5520 <br />2.7549 <br />3.3501 <br />Test End Time: <br />12:45 <br />12:45 <br />1:45 <br />1:45 <br />Final Reading (RF): <br />2.7835 <br />1.5518 <br />2.7550 <br />3.3504 <br />Test Duration: <br />15 MIN <br />15 MIN <br />15 MIN <br />15 MIN <br />Chane in Reading (RF -Rt): <br />0.0003 <br />0.0002 <br />0.0001 <br />0.0003 <br />Pass/Fail Threshold or Criteria: <br />0.002 <br />0.002 <br />0.002 <br />0.002 <br />Test:Result: <br />Pass❑.Fail: <br />- <br />JZPass FII <br />"Piss Fail " <br />Pass ` ❑Fail <br />Was sensor removed for tes tin ? <br />Yes No El NA <br />Z Yes Lj No ❑ NA <br />) <br />N Yes ❑ No NA <br />Was sensor properly replaced and <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />verified functional after testin , <br />Comments — (include information on repairs made prior to testi, and recommended follow-up for failed tests) <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to My of the questions indicated with an <br />asterisk(*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />Secondary Containment Test Results 5 of 7 <br />