My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PICCOLI
>
1990
>
2300 - Underground Storage Tank Program
>
PR0231820
>
COMPLIANCE INFO_2002-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 10:16:48 AM
Creation date
6/23/2020 6:52:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2008
RECORD_ID
PR0231820
PE
2361
FACILITY_ID
FA0003826
FACILITY_NAME
Supervalu
STREET_NUMBER
1990
Direction
N
STREET_NAME
PICCOLI
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
10121001
CURRENT_STATUS
01
SITE_LOCATION
1990 N PICCOLI RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231820_1990 N PICCOLI_2002-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
299
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 5 of 6 <br />7. UNDER -DISPENSER CONTAINMENT (UDC) TESTING <br />Test Method Developed By: <br />❑ UDC Manufacturer <br />❑ Other (Specify) <br />X lry swwad ❑ Professional Engineer <br />Test Method Used: <br />❑ Pressure <br />❑ Other (Specify) <br />❑ Vacuum X Hydrcetwc <br />Test Equipment Used: INCON TS -STS V2.1 <br />- UDC # RLsp 01 UDC # <br />UDC Manufacturer: Total Containment <br />Equipment Resolution: 0.0000" <br />UDC # UDC # <br />UDC Material: <br />Plastic <br />UDC Depth: <br />24" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />6" <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />4" <br />Condition of UDC prior to <br />testing: <br />Clean <br />Portion of UDC Tested <br />None <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?* <br />X Yes ❑ No ❑ NA <br />Turbine shutdown response time <br />4 Seconds <br />Is system programmed mmed for fail- <br />safe shutdown? <br />X Yes ❑ No ❑ NA <br />Was fail-safe verified to be <br />o rational?' <br />X Yes ❑ No ❑ NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />Test Start Time: <br />Visual Fail <br />Initial Reading (RI): <br />Test Erni Time. <br />Final Reading (RF): <br />Test Duration: <br />Change in Reading (RF-Rq): <br />Pass/Fad Threshold or Criteria: <br />0.0020" <br />Test Result: <br />❑ Pass X to <br />Was sensor removed for testing? <br />X Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testin ? <br />X Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up far failed tests) <br />_Dish 01 Electrical penetration on west side of under dispenser containment <br />box is torn. <br />All Hydrostatic Test Performed Twice To Ensure Testinp, Results. <br />' If the entire depth of the UDC is not tested, specify how much was tested If the answer to M of the questions indicated with an <br />asterisk(*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.