My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AD ART
>
3330
>
2300 - Underground Storage Tank Program
>
PR0231901
>
COMPLIANCE INFO_2005-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 10:41:24 AM
Creation date
6/23/2020 6:53:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2018
RECORD_ID
PR0231901
PE
2361
FACILITY_ID
FA0003825
FACILITY_NAME
CALIFORNIA HIGHWAY PATROL #265*
STREET_NUMBER
3330
Direction
N
STREET_NAME
AD ART
STREET_TYPE
RD
City
STOCKTON
Zip
95215
CURRENT_STATUS
02
SITE_LOCATION
3330 N AD ART RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231901_3330 N AD ART_2005-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
443
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7SWRCB, January 2002 <br />8. FILL RISER CONTAINMENT SUMP TESTING <br />Page 6 of 7 <br />Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: <br />❑ Sump Manufacturer <br />❑ Other (Specify) <br />® Industry Standard ❑ Professional Engineer <br />Test Method Used: <br />❑ Pressure <br />❑ Other (Specify) <br />❑ Vacuum ® Hydrostatic <br />Test Equipment Used: INCON STS <br />Fill Sump # 1 <br />Equipment Resolution:.002 <br />Fill Sump # Fill Sump # <br />Fill Sump # <br />rSumpameter: <br />37" <br />epth: <br />48" <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />18" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />20" <br />Condition of sump prior to testing: <br />Good <br />Portion of Sump Tested <br />2" Above piping <br />Penetration <br />Sump Material: <br />Fiberglass <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />15 Minutes <br />Test Start Time: <br />10:58/11:13 <br />Initial Reading Ri): <br />3.2847/3.2838 <br />Test End Time: <br />11:13/11:28 <br />Final Reading (RF): <br />3.2839/3.2837 <br />Test Duration: <br />2-15 Minute Tests <br />Change in Reading RF-Ri): <br />.0008/.0001 <br />Pass/Fail Threshold or Criteria: <br />.002/.002 <br />Test Result: <br />N Pass ❑ Fail <br />❑ Pass ❑ Fail ❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Is there a sensor in the sump? <br />® Yes ❑ No <br />❑ Yes ❑ No ❑ Yes ❑ No <br />❑ Yes ❑ No <br />Does the sensor alarm when either <br />or water is detected? <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />-product <br />Was sensor removed for testing? <br />® Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />® Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.