Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />1 If the entire depth of the sump is not tested, specify how much was tested. If the answer to gny of the questions indicated with an asterisk (*) is "NO" or <br />"NA", the entire sump must be tested. (SWRCB LG -160) <br />SWRCB. January 2002 <br />Page 4 of 7 <br />CHP <br />Stockton, CA <br />01/02/04 <br />6. PIPING SUMP TESTING <br />Test Method Developed By: <br />[ ] Sump Manufacturer [X] Industry Standard <br />[ ] Professional <br />Engineer <br />[ ] Other (Spec) <br />Test Method Used: <br />[ ] Pressure <br />[ ] Vacuum <br />[X ] Hydrostatic <br />[ Other S eci <br />Test E ui ment Used: CALDWELL LEVEL GAUGE <br />E ui ment Resolution: 0.0025 <br />Sump #1 <br />S mp Diameter: <br />42 INCH <br />Sump Depth: <br />24 INCH <br />Sump Material: <br />FIBERGLASS <br />Height from Tank Top to Top of <br />8 INCH <br />Highest Piping Penetration: <br />Height from Tank Top to Lowest <br />10 INCH <br />Electrical Penetration: <br />Condition of sump prior to testing: <br />DRY <br />Portion of Sump Tested <br />12 INCH <br />Does turbine shut down when sump <br />[X] YES [ <br />] NO <br />[ ] YES [ ] NO <br />[ ] YES[ ] NO <br />[ ] YES [ ] NO <br />sensor detects liquid (both product & <br />[ ] NA <br />[ ] NA <br />[ ] NA <br />[ ] NA <br />water)? <br />Turbine shutdown response time: <br />Is system programmed for fail-safe <br />[ ] YES [ <br />] NO <br />[ ] YES[ ] NO <br />[ ] YES [ ] NO <br />[ ] YES [ ] NO <br />shutdown? <br />[X ] NA <br />[ ] NA <br />[ ] NA <br />[ ] NA <br />Was fail-safe verified to be <br />[ ] YES [ <br />] NO <br />[ ] YES [ ] NO <br />[ ] YES [ ] NO <br />[ ] YES [ ] NO <br />operational? <br />[X] NA <br />[ ] NA <br />[ ] NA <br />[ ] NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />5 MIN. <br />test: <br />Test Start Time: <br />10:15 AM <br />Initial Reading (RI): <br />12 INCH <br />Test End Time: <br />10:45 AM <br />Final Reading <br />12 INCH <br />Test Duration: <br />HALF HOUR <br />Chane in Reading Rf-R1 <br />-0- <br />Pass/Fail Threshold or Criteria: <br />.0005 <br />TestlElssttit: ': <br />[` I PASS' <br />[ ,] FAIL ` <br />[,,]„PASS [ ,l FAIL <br />[ ] PASS � ]FAIL <br />[,I PASS-f ].NO <br />Was sensor removed for testing? <br />[ ] YES <br />[ ] NO <br />[ ] YES [ ] NO <br />[ ] YES [ ] NO <br />[ ] YES [ ] NO <br />NA <br />NA <br />NA <br />NA <br />Was sensor properly replaced and <br />[ ] YES <br />[ ] NO <br />[ ] YES [ ] NO <br />[ ] YES [ ] NO <br />[ ] YES [ ]Nd <br />verified functional after testine? <br />[ ] N/A <br />[ ] N/A <br />[ ] N/A <br />[ ] NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />1 If the entire depth of the sump is not tested, specify how much was tested. If the answer to gny of the questions indicated with an asterisk (*) is "NO" or <br />"NA", the entire sump must be tested. (SWRCB LG -160) <br />