My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AD ART
>
3330
>
2300 - Underground Storage Tank Program
>
PR0231901
>
COMPLIANCE INFO_2005-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 10:41:24 AM
Creation date
6/23/2020 6:53:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2018
RECORD_ID
PR0231901
PE
2361
FACILITY_ID
FA0003825
FACILITY_NAME
CALIFORNIA HIGHWAY PATROL #265*
STREET_NUMBER
3330
Direction
N
STREET_NAME
AD ART
STREET_TYPE
RD
City
STOCKTON
Zip
95215
CURRENT_STATUS
02
SITE_LOCATION
3330 N AD ART RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231901_3330 N AD ART_2005-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
443
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB. January 2002 <br />CHP <br />Stockton, CA <br />01/02/04 <br />Page 5 of 7 <br />7. ITNDER-DISPENSER CONTAINMENT WDO TESTING <br />Test Method Developed By: [ ] UDC Manufacturer [X ] Industry Standard [ ] Professional Engineer <br />[ ] Other (Spec) <br />Test Method Used: [ ] Pressure [ ] Vacuum [X] Hydrostatic <br />[ ] Other (Specify) <br />Test Equipment Used: CALDWELL SYSTEM Equipment.Resolution: 0.0025 <br />UDC 4UIiC <br />]# <br />iJDC # <br />UDC # <br />Western Fiberglass <br />UDC Manufacturer: <br />UDC Material: <br />Fiberglass <br />UDC Depth: <br />Height from UDC Bottom to <br />Top of Highest Piping <br />6 INCH <br />Penetration: <br />Height from UDC Bottom to <br />Lowest Electrical <br />5 INCH <br />Penetration: <br />Condition of UDC prior to <br />DRY-CLEAN <br />testing: <br />Portion of UDC Testedl <br />8 INCH <br />Does turbine shut down <br />[X] YES [ ] NO <br />[ ] YES [ ] NO <br />[ ] YES [ ] NO <br />[ ] YES [ ] NO <br />when UDC sensor detects <br />[ ] NA <br />[ ] NA <br />[ ] NA <br />[ ] NA <br />liquid (both product & <br />water)? <br />Turbine shutdown response <br />2 — 3 SECOND <br />time: <br />Is system programmed for <br />[ ] YES [ ] NO <br />[ ] YES[ ] NO <br />[ ] YES [ ] NO <br />[ ] YES [ ] NO <br />fail-safe shutdown? <br />NA <br />NA <br />NA <br />NA <br />Was fail-safe verified to be <br />[ ] YES [ ] NO <br />[ ] YES [ ] NO <br />[ ] YES [ ] NO <br />[ ] YES [ ] NO <br />operational? <br />NA <br />NA <br />NA <br />[ ] NA <br />Wait time between applying <br />pressure/vacuum/water & <br />5 MINS. <br />starting test <br />Test Start Time: <br />10:30 AM <br />Initial Reading (RI): <br />8 INCH <br />Test End Time: <br />11:00 AM <br />Final Reading <br />8 INCH <br />Test Duration: <br />30 MINUTES <br />Chane in Reading f-Rl <br />-0- <br />Pass/Fail Threshold or <br />-0-. <br />Criteria: <br />I est Resutt: <br />PASS FALL , <br />PASS ; , 7=.Ai <br />PASS I FAIL <br />I j PASS FAIL, <br />Was sensor removed for <br />[X] YES [ ] NO <br />[ ] YES [ ] NO <br />[ ] YES [ ] NO <br />testing? <br />N/A <br />N/A <br />N/A <br />Was sensor properly replaced <br />[ X] YES [ ] NO <br />[ ] YES [ ] NO <br />[ ] YES [ ] NO <br />and verified functional after <br />[ ] N/A <br />[ ] N/A <br />[ ] N/A <br />test? <br />Comments — (include information on repairs made prior to testing, and recommended tonow-up for taueo tests <br />1 If the entire depth of the UDC is not tested, specify how much was tested. If the answer to pny of the questions <br />indicated with an asterisk (*) is "NO" or "NA", the entire sump must be tested. (SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.