My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AD ART
>
3330
>
2300 - Underground Storage Tank Program
>
PR0231901
>
COMPLIANCE INFO_2005-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 10:41:24 AM
Creation date
6/23/2020 6:53:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2018
RECORD_ID
PR0231901
PE
2361
FACILITY_ID
FA0003825
FACILITY_NAME
CALIFORNIA HIGHWAY PATROL #265*
STREET_NUMBER
3330
Direction
N
STREET_NAME
AD ART
STREET_TYPE
RD
City
STOCKTON
Zip
95215
CURRENT_STATUS
02
SITE_LOCATION
3330 N AD ART RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231901_3330 N AD ART_2005-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
443
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB. January 2002 <br />CHP <br />Stockton, CA <br />1/02/04 <br />8. FILL RISER CONTAINMENT SUMP TESTING <br />Page 6 of 7 <br />Facility is Not Equipped With Fill Riser Containment Sumps <br />Fill Riser Containment Sumps are Present, but were Not Tested [ ] <br />Test Method Developed By: <br />[ ] Sump Manufacturer [X] Industry Standard [ ] Professional Engineer <br />[ ] Other (Specify) <br />Test Method Used: <br />[ ] Pressure [ ] Vacuum [X ] Hydrostatic <br />[ ] Other (Specify) <br />Test Equipment Used: <br />Equipment Resolution: <br />Fill Sum # Fill Sum # <br />Fill Sum # Fill Sum # <br />Sump Diameter: <br />42 INCH <br />Sump Depth: <br />25 INCH <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />I 1 INCH <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />12 FT <br />Condition of Sump prior to <br />testing: <br />DRY <br />Portion of Sump Tested <br />14 INCH <br />Sump Material: <br />Fiberglass <br />Wait time between applying <br />pressure/vacuum/water & starting <br />test <br />5 MIN. <br />Test Start Time: <br />10:30 AM <br />Initial Reading (111): <br />14 INCH <br />Test End Time: <br />11:30 AM <br />Final Reading <br />14 INCH <br />Test Duration: <br />HALF HOUR <br />Chane in Readin f -RI) <br />Pass/Fail Threshold or Criteria: <br />-0- <br />Test Result: <br />4X I PASS I I FAIL PASS, ; FAIL <br />PASS , - - FAIL PASS I I FAIL > <br />Is there a sensor in the sump? <br />[X]Yes[ No INA Yes No INA <br />Yes ] No NA Yes No NA <br />Does the sensor alarm when either <br />product or water is detected? <br />[ ] Yes [ ] No [ INA [ ]Yes [ ] No [ INA <br />[ ] Yes [ ] No [ INA [ ] Yes [ ]No [ ] NA <br />Was sensor removed for testing? <br />[X ] Yes [ ]No[ ] [ ] Yes [ ] No [ ]N/A <br />NA <br />[ ] Yes [ ] No [ ] N/A [ ] Yes [ ]No[ ] N/A <br />Was sensor properly replaced and <br />verified functional after testing? <br />I [X ] Yes [ ] No [ ] [ ] Yes [ ] No [ ] N/A <br />NA i <br />[ ] Yes [ ]No[ ]N/A [ ] Yes [ ] No [ ]N/A <br />I I <br />Comments — (include information on repairs made prior to testing, and recommended tollow-up Tor tailed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.