My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1501
>
2300 - Underground Storage Tank Program
>
PR0231989
>
COMPLIANCE INFO_2008-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2022 8:46:42 AM
Creation date
6/23/2020 6:54:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2016
RECORD_ID
PR0231989
PE
2361
FACILITY_ID
FA0003976
FACILITY_NAME
VALLEY PACIFIC CHARTER WAY CARDLOCK
STREET_NUMBER
1501
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337016
CURRENT_STATUS
01
SITE_LOCATION
1501 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231989_1501 W CHARTER_2008-2016.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
383
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
03/18/2015 02:13PM 6616349233 KERN CONSTRUCTION PAGE 18/27 <br /> SWRCB,January 2002 Page 5- of <br /> 7. UNDER-DISPENSER CONTAINMENT UDC TESTING <br /> Test Method Developed By: ❑UDC Manufacturer x Industry Standard ❑Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum x Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used:lncon is-sts Equipment Resolution:.001" <br /> UDC#7 Sat UDC#3-4 UDC#5-6 Sat UDC#6-7 <br /> UDC Manufacturer: Bravo <br /> UDC Material: Steel <br /> UDC Depth: 12" <br /> Height from UDC Bottom to Top 0" <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to 0" <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to Clean <br /> testing: <br /> Portion of UDC Tested' 1/2 <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yes ❑No X NA ❑Yes ❑No ❑NA ❑Yes ❑No DNA ❑Yes ❑No ❑NA <br /> product and water)?* <br /> Turbine shutdown response time <br /> j Is system programmed for fail- <br /> safe shutdown?` ❑yes ❑No X NA ❑Yes ❑No ❑NA 0 Yes ❑No ❑NA ❑Yes ❑No DNA <br /> Was fail-safe verified to be ❑yes ❑No X NA ❑Yes D No DNA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> operational?* <br /> Wait time between applying 15 min. <br /> pressure/vacuum/water and <br /> starting test <br /> Test Start Time: 9:15 <br /> Initial Reading(Ri): 0.620 <br /> Test End Time: 9:30 <br /> Final Reading(RF): 0.619 <br /> Test Duration: 15 Min <br /> Change in Reading(RF-RI): 0.001 <br /> Pass/Fail Threshold or Criteria: 0.002 <br /> Test:Result: X..Pass .0 Fail ❑ Pass ❑Fail D;Pass .d Fail_': i1.Pass`°:.OFgil <br /> Was sensor removed for testing? 0 Yes ❑No X NA ❑Yes ONO DNA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and ❑Yes ❑No X NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes D No ❑NA <br /> verified functional after testing? 11 <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> MAR 19 2015 <br /> ENVIRONMI Tei <br /> !Jr'� T►.7 <br /> 05 -r <br /> 'If the entire depth of the UDC is not tested,specify how much was tested. If the answer to my of the questions indicated with an <br /> asterisk(*)is`NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br /> Received Time Mar. 18, 2015 3: 16PM No. 8366 <br />
The URL can be used to link to this page
Your browser does not support the video tag.