My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1501
>
2300 - Underground Storage Tank Program
>
PR0231989
>
COMPLIANCE INFO_2008-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2022 8:46:42 AM
Creation date
6/23/2020 6:54:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2016
RECORD_ID
PR0231989
PE
2361
FACILITY_ID
FA0003976
FACILITY_NAME
VALLEY PACIFIC CHARTER WAY CARDLOCK
STREET_NUMBER
1501
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337016
CURRENT_STATUS
01
SITE_LOCATION
1501 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231989_1501 W CHARTER_2008-2016.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
383
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
03/18/2015 02:13PM 6616349233 KERN CONSTRUCTION PAGE 16/27 <br /> SWRCB,January 2002 Page 3 of <br /> 5. SECONDARY PIPE TESTING <br /> Test Method Developed By: ❑Piping Manufacturer x Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: x Pressure ❑Vacuum ❑Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used:4"dial gauge Equipment Resolution:0-15 psi <br /> Piping Run#DSL Piping Run#87 Piping Run#Sat 6 Piping Run#Sat 7 <br /> Piping Material: FRP FRP FRP FRP <br /> Piping Manufacturer: Ameron Ameron Ameron Ameron <br /> Piping Diameter: 3" 3" 3" 3" <br /> Length of Piping Run: 50' 50, 15' 15' <br /> Product Stored: DSL 87 DSL DSL <br /> Method and location of Test boot Test boot Riser Riser <br /> i in -run isolation: <br /> Wait time between applying <br /> pressure/vacuum/water and 30 min. 30 min. 30 Min. 30 Min. <br /> starting test: <br /> Test Start Time: 7:00 7:00 8:45 10:20 <br /> Initial Reading(Ri): 5.0 PSI 5.2 PSI 5.0 PSI 5.0 PSI <br /> Test End Time: 12:00 12:00 9:45 10:20 <br /> Final Reading(RF): 5.0 PSI 4.5 PSI 5.0 PSI 5.0 PSI <br /> Test Duration: 1 HR. 1 HR. 1 HR 1 HR <br /> Change in Reading(RF-Rr): 0 PSI 0.7 PSI 0.0 PSI 0.0 PSI <br /> Pass/Fail Threshold'or 0 PSI 0.0 PSI 0.0 PSI <br /> Criteria: 0 PSI <br /> Test Results_ X Pass ❑Fail ❑ Pass X F ail X Pass ❑,Fail X Pass'. ;p 2+'ari <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> MAR 18 ZU15 <br /> ENVIRCINAAMIT„t <br /> Received Time Mar. 18. 2015 3: 16PM No. 8366 <br />
The URL can be used to link to this page
Your browser does not support the video tag.