My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2375
>
2300 - Underground Storage Tank Program
>
PR0232469
>
COMPLIANCE INFO_2008-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2021 2:40:22 PM
Creation date
6/23/2020 6:56:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2011
RECORD_ID
PR0232469
PE
2361
FACILITY_ID
FA0003772
FACILITY_NAME
GRANT LINE SHELL*
STREET_NUMBER
2375
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21402017
CURRENT_STATUS
01
SITE_LOCATION
2375 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\2375\PR0232469\FINAL JUDGMENT 11-06-09.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
564
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JUN -04-2008 14:44 Service Station Systems 408 938 8888 P.O? <br />Test Method Developed By: <br />❑ Stunp Manufacturer <br />❑ Other (Specify) <br />® Industry Standard ❑ Professional Engineer <br />Test Method Used: <br />❑ Pressure <br />❑ Other (Specify) <br />❑ Vacuum <br />® Hydrostatic <br />Test Equipment Used: Incon Sump Tester <br />STP Sump # 87 A <br />"Sumpiameter: 42" <br />STP Sump # 87 B <br />42" <br />Equipment Resolution: +/- 0.002" <br />STIP Sump # 89 A STP Sump # 89 B <br />42" 42" <br />Sump I?epth: <br />SO" <br />KO" <br />80" <br />80" <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />14" <br />14" <br />14" <br />14" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />22" <br />22„ <br />2291 <br />22" <br />Condition of sump prior to testing: <br />Good <br />Good <br />Good <br />Good <br />Portion of Sump Tested' <br />2" above piping <br />2" above piping <br />2" above piping <br />2" above piping <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water ?41 <br />ElYes [INo ® NA <br />ElYes ❑ No ®NA <br />❑ Yes ❑ No ®NA <br />❑ Yes 1:1No RNA <br />Turbine shutdown response time <br />N/A <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail -Safe <br />shutdown?" <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No RNA <br />❑ Yes ❑ No ®NA <br />❑ Yes ❑ No ®NA <br />Was fail-safe verified to be <br />operational?® <br />® Yes ❑ No ® NA <br />❑ Yes ❑ No ®NA <br />❑ Yes ❑ No ®NA <br />❑ Yes ❑ No ®NA <br />Wait time between applying <br />pressure✓vacuum/water and starting <br />test: <br />30 minutes <br />30 minutes <br />30 minutes <br />30 minutes <br />Test Start Time: <br />12:15 pm <br />11:06 am <br />12:15 pm <br />12:15 pm <br />.Initial Reading (R,): <br />5.6934 <br />4.8910 <br />3.5379 <br />4.1362 <br />Test End Time: <br />12:31 pm <br />11:21 am <br />12:30 pm <br />12:30 pm <br />Final Reading (Rv): <br />5.5978 <br />4.8907 <br />3.5390 <br />4.1342 <br />Test Duration: <br />16 min. <br />15 ruin. <br />15 min. <br />15 min. <br />Change in Reading (RF�Ri): <br />-0.0956 <br />-0.0003 <br />+0.001' <br />-0.020 <br />Pass/Fail Threshold or Criteria: <br />4-0.0021, <br />+/-0.00211 <br />+/.0.00211 <br />+/- 0.002" <br />Test Result: <br />lass ® Fail <br />® Pass Fail <br />® Pass Fail <br />Pass [R] ail <br />Was sensor removed for testing? <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ® NA <br />® Yes ❑ No []NA <br />® Yes ❑ No ❑NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />®Yes E) No ❑ NA <br />Yes ❑ No p NA <br />®Yes ❑ No []NA <br />®Yes ❑ No ❑NA <br />COMMentS — (include information on repairs made prior to testiM, and recommendedfollow-ffE&Lfailed tests) <br />'Sensor functionality was not confirmed. This procedure is <br />not part of the Secondary Containment testing scope of work". <br />87 A and 89 B failed. Possible piping penetrations <br />' If the entire depth of the sump is not tested, specify how much was tested. if the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.