My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2375
>
2300 - Underground Storage Tank Program
>
PR0232469
>
COMPLIANCE INFO_2008-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2021 2:40:22 PM
Creation date
6/23/2020 6:56:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2011
RECORD_ID
PR0232469
PE
2361
FACILITY_ID
FA0003772
FACILITY_NAME
GRANT LINE SHELL*
STREET_NUMBER
2375
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21402017
CURRENT_STATUS
01
SITE_LOCATION
2375 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\2375\PR0232469\FINAL JUDGMENT 11-06-09.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
564
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JUN -04-2008 14:44 Service Station Systems 408 938 8888 P.09 <br />9. UNDER -DISPENSER CONTAINMENT (UDC} TESTING <br />Test Method Developed By: ❑ UDC: Manufacturer R Industry Standard ❑ Professional Engineer <br />Q Other (Specify) <br />Test Method Used: Q Pressure Q Vacuum R Hydrostatic <br />® Other (specify) <br />Test Eauioment Used: Incon Sump Tester Equipment Resolution: +/- 0.002" <br />Comments — Onelude!tLorm dan on repairs made prior to testing, and recommended follow-upforfailed tests) <br />"Sensor .Functionality was not confirme& This procedure is not part of the Secondary Containment testing scope of work", <br />r If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />UDC #1/2 <br />UAC # 3/4 <br />UDC # 5/6 <br />UDC # 7/8 <br />712Canufacturer: <br />OPW <br />OlPW <br />OPW <br />OPW <br />aterial: <br />Plastic <br />Plastic <br />Plastic <br />Plastic <br />e the <br />31" <br />31" <br />31" <br />31" <br />Height from UDC bottom to Top <br />of Hi est Piping Penetration: <br />19" <br />19" <br />19" <br />19" <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />` j •• <br />11" <br />i l" <br />l i" <br />Condition of UDC prior to <br />testim: <br />Good <br />Good <br />Good <br />Good <br />Portion of UDC Tested <br />2" above piping <br />2" above piping <br />2" above piping <br />2" above 21ping <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />roduct and water)?` <br />❑ Yes ❑ No R NA <br />Q Yes Q No ®NA <br />p Yes ❑ No RNA <br />❑ Yes ❑ No RNA <br />Turbine shutdown respow" time <br />N/A <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail- <br />safe shutdown?' <br />❑Yes E3No ®NA <br />ElYes p No ®NA <br />❑Yes ❑ No RNA <br />[j Yes ❑ No RNA <br />Was fail-safe verified to be <br />o rational?° <br />Q .Yes ❑ No ® NA <br />❑ Yes ❑ No RNA <br />❑ Yes Q No ®NA <br />Q Yes ❑ No ®NA <br />Wait time between applying <br />pressure/vacuum/water and <br />startins test <br />30 minutes <br />30 minutes <br />30 minutes <br />30 minutes <br />Test Start Time: <br />7:24 am <br />6:33 am <br />4,51 EM <br />7:24 am <br />Initial Reading (Rt): <br />2.2100 <br />2.4460 <br />6.1134 <br />4.7088 <br />Test End Time: <br />7:39 anu <br />6:48 am <br />5:06 RM <br />7:39 am <br />Final Reading (RF): <br />2.2099 <br />2.4459 <br />6.1135 <br />4.7087 <br />Test Duration: <br />15 min. <br />15 min. <br />15 min. <br />15 min. <br />Chane in Reading (RrRa): <br />•0,0001 <br />-0.0001 <br />+0.0001 <br />-0.0001 <br />Pass/Fail Threshold or Criteria: <br />+/- 0.002" <br />+/-0.0071 <br />+/- 0.002" <br />+/- 0.002" <br />Test Result: <br />® Pass Fait <br />® Pass Fail <br />0 Parrs Fail <br />® Pass Fail <br />Was sensor removed for testing? <br />R Yes ❑ No ❑ NA <br />R Yes ❑ No ❑ NA <br />R Yes (a No QNA <br />R Yes Ej No QNA <br />Was sensor properly replaced and <br />verified functional after testin ? <br />R Yes D No ❑ NA <br />Yes q No Q NA <br />®Yc .a ❑ No ❑NA <br />®Yes E]No [JNA <br />Comments — Onelude!tLorm dan on repairs made prior to testing, and recommended follow-upforfailed tests) <br />"Sensor .Functionality was not confirme& This procedure is not part of the Secondary Containment testing scope of work", <br />r If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.