My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2375
>
2300 - Underground Storage Tank Program
>
PR0232469
>
COMPLIANCE INFO_2008-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2021 2:40:22 PM
Creation date
6/23/2020 6:56:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2011
RECORD_ID
PR0232469
PE
2361
FACILITY_ID
FA0003772
FACILITY_NAME
GRANT LINE SHELL*
STREET_NUMBER
2375
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21402017
CURRENT_STATUS
01
SITE_LOCATION
2375 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\2375\PR0232469\FINAL JUDGMENT 11-06-09.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
564
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JUN -04-2008 14:44 Service Station Systems 408 938 8888 P.10 <br />m <br />Test Method Developed By: <br />❑ UDC Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: <br />❑ Pressure <br />❑ Vacuum <br />hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: Incon Sump Tester <br />Equipment Resolution: <br />+/- 0.002" <br />UDC #9/10 <br />UDC # 11/12 <br />(.FDC # 13/14 <br />UDC # 15/16 <br />MUM M.J. mmum <br />UDC Manufacturer: <br />OPW <br />OPW <br />OPW <br />OPW <br />UDC Material: <br />Plastic <br />Plastic <br />Plastic <br />Plastic <br />UDC Depth: <br />31'° <br />31" <br />31" <br />31,. <br />1 <br />Height from UDC Bottom to Top <br />19„ <br />19=, <br />19 <br />19" <br />of Hi est Pim Penetration: <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />Condition of UDC prior to <br />Good <br />Good <br />Good <br />Good <br />testing- <br />estin :Portion <br />Portionof UDC Tested <br />2" above piping <br />2" above piping <br />2" above piping <br />2" above i ing <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />[jYes ElNo ® NA <br />❑ Yes L]No ®NA <br />❑ Yes [jNo ONA <br />L]Yes [:]No ®NA <br />product and water)?° <br />Turbine shutdown response time <br />N/A <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail- <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ®NA <br />❑ Yes ❑ No ®NA <br />❑ Yes ❑ No ®NA <br />safe shutdown?* <br />Was fail-safe verified to be <br />® Yes ❑ No M NA <br />❑ Yes ❑ No IMNA <br />❑ Yes ❑ No ®NA <br />❑ Yes ❑ No ®NA <br />operational?* <br />Wait time between applying <br />pressure/vacuum/water and <br />30 minutes <br />30 minutes <br />30 minutes <br />30 minutes <br />starting test <br />Test Start Time: <br />4:51 pm <br />7:24 am <br />6:33 am <br />4:51 prn <br />In <br />5.0681 <br />3.2918 <br />3.0560 <br />5.4866 <br />Test End Time: <br />5:07 am <br />7:40 am <br />6:48 am <br />5:07 am <br />Final Reading (RF): <br />5.0674 <br />3.2918 <br />3.0545 <br />5.4864 <br />Test Duration: <br />16 min. <br />16 min. <br />i5 men. <br />16 min. <br />Chane in Reading (P+ R,): <br />-0.0007 <br />None <br />-0.0015 <br />-0.0002 <br />Pass/Fail Threshold or Criteria: <br />+/- 0.002" <br />+/- 0.002°' <br />+/- 0.002" <br />4-0.00211 <br />Test Result: <br />© pass Fail <br />® Pass Fail <br />® Pass Fail <br />® Pass Fail <br />Was sensor removed for testing? <br />M Yes ❑ No ❑ NA <br />® Yes ® No ❑ NA <br />® Yes ❑ No ❑NA <br />® Yes ❑ No ❑NA <br />Was sensor properly replaced and <br />® Yes ❑ No ® NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑NA <br />0 Yes ❑ No [INA <br />verified functional after testing? <br />Comments — (include information on repairs made prior to testing, and recommendedfoUow-up forfailed tests) <br />"Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment testing scope of work". <br />1 If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk M is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.