My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2375
>
2300 - Underground Storage Tank Program
>
PR0232469
>
COMPLIANCE INFO_2008-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2021 2:40:22 PM
Creation date
6/23/2020 6:56:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2011
RECORD_ID
PR0232469
PE
2361
FACILITY_ID
FA0003772
FACILITY_NAME
GRANT LINE SHELL*
STREET_NUMBER
2375
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21402017
CURRENT_STATUS
01
SITE_LOCATION
2375 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\2375\PR0232469\FINAL JUDGMENT 11-06-09.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
564
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JUN -04-2008 14:50 Service Station Systems 408 938 8888 P.18/19 <br />0 0 <br />5. FILL RISFR CONTAINMENT SUMP TESTING <br />Facility is Not Equipped With Fill Riser Containment Sumps p <br />Fill Riser Containment Sumps are Present, but were Not Tested p <br />Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard p Professional Engineer <br />0 Other (Specify) <br />Test Method Used: p Pressure p Vacuum ® Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: Incon Sump Tester Equipment Resolution: +1- 0.002" <br />Fill Sump # ASL <br />Sum Diameter: 42" <br />Sump the 82" <br />height from Tank Top to Top of N/A <br />Highest Piping Penetration: <br />Height from Tank Top to Lowest 20" <br />Electrical Penetration: <br />Condition of sump prior to Good <br />testiri : <br />Portion of SuR Tested 2" above pIP12A <br />juing Material: Fiberglass <br />Wait time between applying <br />pressurelvacuum/water and 30 minutes <br />starting test <br />Test Start Time: 10:13 am <br />Initial Reading (RI): 3.8924 <br />Test End Time: 10:28 am <br />Final Reading (RF): 3.8931 <br />Test Duration: 1s min. <br />Change in Readin (RF-RO: +0,0007 <br />Pass/Fail Threshold or Criteria: +/-0.002" <br />Test Result: ® Pass Fail <br />Is there a sensor in the sum ? ® Yes 0 No <br />Does the sensor alarm when <br />either product or water is ® Yes Cl No ® NA <br />detected? <br />Was sensor removed for testin ?® Yes p No p NA <br />Was sensor properly replaced and <br />verified functional after testing? � Yes p No p NA <br />Comments M (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />"Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment testing scope of work". <br />Retest only <br />
The URL can be used to link to this page
Your browser does not support the video tag.