Laserfiche WebLink
SWRCB, January 2002 Page 5 of 7 <br />7. <br />Test Method Developed By: <br />UNDER -DISPENSER CONTAINMENT UDC TESTING <br />❑ UDC Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: <br />❑ Pressure <br />❑ Other (Specify) <br />❑ Vacuum <br />® Hydrostatic <br />Test Equipment Used:Incon TS -STS <br />7UDC <br />UDC Manufacturer: <br />#16 <br />UDC #19Main <br />Equipment Resolution: +/-0.0001" <br />UDC #20Main UDC #21 Main <br />UDC Material: <br />FRP <br />FRP <br />FRP <br />FRP <br />UDC Depth: <br />30" <br />27" <br />27" <br />27" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />11" <br />6" <br />6" <br />7" <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />N/A <br />5" <br />3" <br />4" <br />Condition of UDC prior to <br />testin : <br />Clean <br />Clean <br />Clean <br />Clean <br />Portion of UDC Tested <br />2"above highest Pipe pen <br />2"above highest Pipe pen <br />2"above highest Pipe pen <br />2"above highest Pipe pen <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?" <br />®Yes ❑No ❑NA <br />❑Yes ❑No ❑NA <br />❑Yes [:]No ❑NA <br />❑Yes ❑No ❑NA <br />Turbine shutdown response time <br />Is system programmed for fail- <br />safe shutdown?` <br />EYes ❑No ❑NA <br />®Yes ❑No RNA <br />®Yes [:]No ❑NA <br />®Yes ❑No ❑NA <br />Was fail-safe verified to be <br />o erational?� <br />❑Yes ❑No❑No <br />®NA <br />❑Yes ❑No ®NA <br />❑Yes ❑No ®NA <br />❑Yes ®NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />15 Minutes <br />15 Minutes <br />15 Minutes <br />15 Minutes <br />Test Start Time: <br />11:13 11:30 <br />3:33 3:50 <br />3:33 3:50 <br />Initial Reading (Rt): <br />4.9944 4.9885 <br />2.6067 2.6062 <br />4.5955 4.5933 <br />Test End Time: <br />11:28 11:45 <br />3:48 4:06 <br />3:48 4:06 <br />Final Reading (RF): <br />4.9886 4.9840 <br />2.6065 2.6056 <br />4.5956 4.5923 <br />Test Duration: <br />15 Min Each (30 Min) <br />15 Min Each (30 Min <br />15 Min Each (30 Min) <br />15 Min Each (30 Min) <br />Change in Reading (RF-Ri): <br />0.0058 1 0.0045 <br />1 <br />0.0002 1 0.0006 <br />0.0001 0.001 <br />Pass/Fail Threshold or Criteria: <br />+/- 0.002" <br />+/- 0.002" <br />+/- 0.002" <br />+/- 0.002" <br />Test Result: <br />❑ Pass ® Fail <br />❑ Pass ® Fail <br />M Pass ❑ Fail <br />® Pass ❑ Fail <br />Was sensor removed for testing? <br />®Yes ❑No DNA <br />®Yes ❑No ❑NA <br />®Yes ❑No ❑NA <br />®Yes ❑No ❑NA <br />Was sensor properly replaced and ❑ ❑ ❑ [-]No❑NA ®Yes ❑No ❑NA <br />verified functional after testin ? ®Yes ❑No NA ®Yes No NA ®Yes <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Under dispenser #16 and 19 main Failed Hydrostatic test. <br />Under dispenser # 20 and 21 main Passed Hydrostatic test. <br />If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />