Laserfiche WebLink
SWRCB,January 2002 Page 10 of 12 <br /> 7. UNDER-DISPENSER CONTAINMENT(UDC)TESTING <br /> Test Method Developed By: I I UDC Manufacturer C Industry Standard [1 Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: Pressure ❑Vacuum x Hydrostatic <br /> Other(Spec) <br /> Test Equipment Used: INCON-TS-STS Equipment Resolution: +/-0.002" <br /> UDC# 1-2 UDC# 3-4 UDC# 5-6 UDC# 7-8 <br /> UDC Manufacturer: Unknown Unknown Unknown Unknown <br /> UDC Material: Fiber lass Fiberglass Fiberglass Fiberglass <br /> UDC Depth: 30" 30" 30" 30" <br /> Height from UDC Bottom to Top 12" 13" 13" 12" <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to 8" 8" 8" 8" <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> Dry Dry Dry Dry <br /> testing: <br /> Portion of UDC Tested' 27 26" 27" 25" <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yes [No k NA 7—Yes ❑No X NA ❑Yes ❑No XI NA ❑Yes ❑No X NA <br /> product and water)?* <br /> Turbine shutdown response time <br /> Is system programmed for fail- <br /> safe shutdown?` ❑Yes [..1No "RNA ❑Yes :]No K NA ❑Yes IJNo L NA Yes ❑No K,NA <br /> Was fail-safe verified to be ❑Yes ❑No XNA -1 Yes ❑No Kc NA ❑Yes ❑No 9 NA ❑Yes ❑No X NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and 15 minutes 15 minutes 15 minutes 15 minutes <br /> starting test <br /> Test Start Time: 09:02am 08:03am 08:44am 10:08am <br /> Initial Reading(RI): 4.4608 3.6844 2.3028 1.6734 <br /> Test End Time: 09:17am 08:18am 08:59am 10:24am <br /> Final Reading(RF): 14.4612 3.6844 2.3026 1.6735 <br /> Test Duration: 15 minutes 15 minutes 15 minutes 15 minutes <br /> Chane in Reading(RF-RI): +0.0004 0.0000 -0.0002 +0.0001 <br /> Pass/Fail Threshold or Criteria: +/-0.002" +/-0.002" +/-0.002" +/-0.002" <br /> Test Result: 19 Pass ❑Fail ® Pass ❑Fail ® Pass ❑Fail N Pass ❑Fail <br /> Was sensor removed for testing? ®Yes ❑No ❑NA X Yes '❑No _NA X Yes ❑No ❑NA J Yes ❑No ❑NA <br /> Was sensor properly replaced and <br /> verified functional after testi n ? Yes ❑No ❑NA X Yes El No LJNA XYes ❑No ❑NA ®Yes ❑No 11NA <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> kjH t4 <br /> NOV <br /> 1Rs <br /> ' If the entire depth of the UDC is not tested,specify how much was tested. If the answer to an of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />