S A N sJ O A Q U I N Environmental Health Department <br /> COUNTY <br /> e. Spill bucket test: Verify minimum 5-gallon capacity and pass a one hour hydrostatic test (or <br /> equivalent). Proper drainage must also be verified. Completed 4/10/2018 <br /> f. Primary piping soap test: One hour pneumatic pressure test at 110% of operating pressure, <br /> or 40 psi, whichever is greater. Completed 3/28/2018 <br /> g. Secondary piping soap test: One hour pressure test per manufacturer's guidelines. If there <br /> are no manufacturer's guidelines, test shall be performed using an applicable method <br /> specified in an industry code or engineering standard. Completed 3/29/2018 <br /> h. 24-hour hydrostatic test (or equivalent) on all impacted UDC sumps and piping impacted. <br /> Completed 3/29/2018 <br /> i. Primary piping test: Witness tightness test performed by SWRCB licensed tank tester or <br /> receive passing 0.1 gallon per hour test results from the PLLD (if installed). A visual <br /> inspection is required for PLLD tested lines. Completed 4/10/2018 <br /> j. Verification of the dispenser footprints contained by the UDC sumps and verification that all <br /> potential product piping leaks will be captured in the UDC. Completed 4/10/2018 <br /> k. Visual inspection of the piping within the dispensers for any product leaks. Completed <br /> 4/10/2018 <br /> I. Since concrete will be broken near the product piping, a secondary containment test must <br /> be performed on the product piping and UDCs once concrete is poured in accordance with <br /> the manufacturer's guidelines. Completed 4/12/2018 <br /> Please be aware that the facility cannot operate the UST prior to the EHD inspection and <br /> approval. <br /> 4. Secondary containment testing for the impacted sumps is required six months after installation. <br /> Provide 48 hours notification to the EHD when this test is scheduled. <br /> 5. In addition, the following information must be submitted within 30 days after the UDCs and <br /> associated piping removal date: <br /> a. Analytical results: only results that come directly from a third party California certified <br /> laboratory with affixed chain of custody will be accepted by EHD. <br /> b. Hazardous Waste Manifest for rinsate and residual product. <br /> 6. Any individual performing the work of a service technician must meet the following <br /> qualifications: <br /> a. Possess or be employed by a person who possesses one of several permissible valid, <br /> current contractor's licenses issued by the Contractors State License Board (may be issued <br /> to the installation company), or a Tank Tester's license issued to the individual by the State <br /> Water Board, and <br /> b. Possess or work under the direct and personal supervision of an individual physically <br /> present at the work site who possesses a valid, current California UST Service Technician <br /> certificate issued by the International Code Council (ICC), and <br /> c. Possesses a valid, current certificate of training from the manufacturer(s) of the <br /> component(s) being tested, repaired, or serviced. <br /> 7. Individuals installing underground storage tank system components must possess or work <br /> under the direct and personal supervision of an individual physically present at the work site <br /> who possesses all of the following: <br /> a. A valid, current contractor's license issued by the Contractors State License Board, and <br /> b. A valid, current UST Installation/Retrofitting certificate issued by the International Code <br /> Council (ICC), and <br /> c. A valid, current certificate of training from the manufacturer(s) of the component(s) being <br /> installed. <br /> 2 of 3 <br />