My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15237
>
2300 - Underground Storage Tank Program
>
PR0517272
>
COMPLIANCE INFO_2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 2:47:40 PM
Creation date
6/23/2020 6:59:19 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008
RECORD_ID
PR0517272
PE
2361
FACILITY_ID
FA0012979
FACILITY_NAME
FLYING J TRAVEL PLAZA #617
STREET_NUMBER
15237
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
02519014
CURRENT_STATUS
01
SITE_LOCATION
15237 N Thornton Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\T\THORNTON\15237\PR0517272\FINAL JUDGMENT ON CONSENT 09-29-08.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
420
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 0 Page 10 <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: F-1 Sump Manufacturer ❑ Industry Standard Professional Engineer <br /> Other (Specify) <br /> Test Method Used: FI Pressure F Vacuum ❑ Hydrostatic <br /> Other (Specify) <br /> Test Equipment Used: vplt Equipment Resolution: vplt to gph <br /> Sump# 1 DIE Sump# 1 I?IE Sump# 1 DIE Sump# <br /> Sump Diameter: 4811 4 5"by4 5" ----- <br /> Sump Depth: 6711 67" -Sump Material: fiberglass fiberglass --- <br /> Height from Tank Top to Top of 2911 23„ -- <br /> Highest Piping Pentration: <br /> Height from Tank Top to Lowest 2211 21” --- <br /> Electrical Pentration: <br /> Condition of sump prior to testing: good good -- <br /> Portion of Sump Tested: 1 311- 2511 <br /> -- <br /> Does turbine shut down when <br /> sump sensor detects liquid(both X❑Yes❑N�N Yes❑NoEN Yes DNo❑N Yes�No�t <br /> product and water)?* <br /> Turbine shutdown response time: 2-5sec 2-5sec -- <br /> Is system programmed for fail-safe FY-1 � � ❑ [:]Yes <br /> ❑ � ❑ ❑ [:] <br /> shutdown?* Yes N N X❑Yes N N Yes N N Yes No <br /> Was fail-safe verified to be � ❑ ❑ ❑ ❑ �T <br /> operational?* X Yes N N X Yes N N X Yes N N X Yes No <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5min 5min - <br /> test: <br /> Test Start Time: 7:16 8:23 <br /> -- <br /> Initial Reading(R1): 7.476 8.524 - <br /> Test End Time: 7:46 8:53 -- <br /> Final Reading(RF): 7.476 8.52 4 - <br /> Test Duration: 3 Omin 3 Omin - <br /> ChangeinReading(RF-RI ): .000gph .000gph -- <br /> Pass/Fail Threshold or Criteria: .05gph .05gph <br /> Was sensor removed for testing? �YesE1NoF]NA mYes❑No❑NA❑Yes❑No❑NA[—]Yes[]No t <br /> Was sensor properly replaced and IflYesE]Nc[:]NA �Ye�N e�N�NA Yes❑N`[:] <br /> verified fnctional after testing? 11 1 ❑ <br /> Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> the sixth and seventh set of data were transition sump one and two consecutively and <br /> transition sump 2 was not tested due to capasity(need more water to test) <br /> 1 If the entire depth of the sump is not tested,specify how much was tested.If the answer to ani,of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />