Laserfiche WebLink
' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />SWRCB, January 2002 Page of <br />7. UNDER -DISPENSER CONTAINMENT UDC TESTING <br />Test Method Developed By: ❑ UDC Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Spec) <br />nt Used: Incon Incon TS -STS Tester Equipment Resolution: +/-0.002" <br />UDC # 9-10 UDC # UDC # UDC # <br />"CDepth:"30" <br />Unknown <br />Fiber lass <br />Height from UDC Bottom to Top <br />20" <br />of Highest Piping Penetration: <br />Height from UDC Bottom to <br />18" <br />Lowest Electrical Penetration: <br />Condition of UDC prior to <br />D <br />Dry <br />testing: <br />Portion of UDC Tested <br />24" <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />❑ Yes []No ® NA <br />❑ Yes ❑ No ® NA ❑ Yes ❑ No 9 NA ❑ Yes ❑ No 9 NA <br />product and water)?* <br />Turbine shutdown response time <br />Is system programmed for fail- <br />❑ Yes []No ® NA <br />❑ Yes ❑ No 9 NA ❑ Yes ❑ No 9 NA ❑ Yes ❑ No ® NA <br />safe shutdown?` <br />Was fail-safe verified to be <br />❑ Yes ❑ No ®NA <br />❑ Yes ❑ No ® NA ❑ Yes ❑ No ® NA ❑ Yes ❑ No ® NA <br />o erational?' <br />Wait time between applying <br />pressure/vacuum/water and <br />15 minutes <br />starting test <br />Test Start Time: <br />3:41 pm 3:58pm <br />Initial Reading (RI): <br />5.4131" 5.4129" <br />Test End Time: <br />3;57pm 4:13pm <br />Final Reading (RF): <br />3.4128" 5.4130" <br />Test Duration: <br />15 Minutes Each 30 <br />Change in Reading RF -RI): <br />-0.0003 0.0001 <br />Pass/Fail Threshold or Criteria: <br />+/-0.002" +/-0.002" <br />Test Result: `' <br />9 Pass ❑ Fail <br />❑ Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br />Was sensor removed for testing? <br />W Yes []No ❑ NA <br />❑ Yes ❑ No ® NA ❑ Yes ❑ No ® NA ❑ Yes ❑ No 9 NA <br />Was sensor properly replaced and <br />k Yes ❑No ❑ NA <br />❑ Yes ❑ No ® NA ❑ Yes ❑ No 9 NA ❑ Yes ❑ No ® NA <br />verified functional after testin ? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />" Unable to test UDC# 1-2,3-4,5-6,7-8,11-12,13,14-15, 16-17 and 18, Due to missing boots and boots air fittings. <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />