My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EIGHTH
>
717
>
2300 - Underground Storage Tank Program
>
PR0522448
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2023 3:02:54 PM
Creation date
6/23/2020 6:59:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0522448
PE
2371
FACILITY_ID
FA0015274
FACILITY_NAME
SHELL I-5
STREET_NUMBER
717
Direction
W
STREET_NAME
EIGHTH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16314045
CURRENT_STATUS
01
SITE_LOCATION
717 W EIGHTH ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0522448_717 W EIGHTH_2016-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
198
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 0 0 Pa -!1 e of —8 - <br />Test Method Developed By: E] Sump Manufacturer Q industry Standard Professional E, gineer <br />E] Other (Speciffi <br />Test Method Used: Fj Pressure 0 Vacuum ®Hydrostatic <br />Ej Other (Specify) <br />Equipment, Used: Caldwell Level Indicator <br />Equipment Resolution: .002 <br />jTest <br />Sump #Unleaded <br />Sump #Premium <br />Sump #Diesel <br />Sump Went <br />Sump ; Diameter: <br />42 <br />42 <br />42 <br />26 <br />Sump Depth: <br />63 <br />63 <br />63 <br />24 <br />Sump Material: <br />fiberglass <br />fiberglass <br />fiberglass <br />l fiberglass <br />Height from Tank Top to Top of <br />Highest Piping Penetration:..._ <br />14.5" <br />14.5" <br />14.5" <br />0 <br />Height from Tank Top to Lowest0 <br />Electrical Penetration: <br />2311 <br />23" <br />Condition of sump prior to testing: <br />clean <br />clean <br />clean <br />dean <br />Portion of Sump Tested' <br />2"above <br />product line <br />2" above <br />product line <br />2"above <br />product line <br />1810 <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)?* <br />Z Yes [:] NoEj NA <br />Z Yes 0 No ❑ NA <br />Z Yes[] NO NA <br />' <br />El [0 No NA <br />Yel <br />... <br />Turbine shutdown response time <br />n/a <br />n/a <br />n/a <br />n/a <br />Is system programmed for fail-safe <br />shutdown?* <br />F ®Yes -] No [3NA <br />®Yes® No 0 NA <br />®Yes® No 0 NA <br />El El No n NA <br />Was fail-safe verified to be <br />oj?erational?* <br />F]yes® NoEl NA <br />[I Yes Z No El NA <br />0 Yes10 NO 1:1 NA <br />11 y 0 NO RNA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />15mins <br />15 's <br />15mins <br />15mins <br />Test Start Time: <br />30 'ns <br />30mins <br />30mins <br />30mins <br />Initial Reading (Rt): <br />first circle <br />first circle <br />first circle <br />first circle <br />Test End Time: <br />omins <br />Ondns <br />Omins <br />Omins <br />Final Reading (RF): <br />no change <br />no change <br />no change <br />no change <br />Test Duration: <br />30'ns30mins <br />30 'ns <br />30mins <br />Change in Reading (RF-RO: <br />0 <br />0 <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />.005/30mins <br />.005/30mins <br />.005/30mins <br />i .005/30mins <br />Test Result: <br />0 Pass El tail <br />Pass 0 Fail <br />Z Pass E) Fail <br />Z J'ass 0 Fail_ <br />Was sensor removed for testing? <br />M Yes n NoEl NA <br />0 YesE] N®Q NA <br />Z Yes[] NoEINA <br />0 s M NoF] NA <br />Was Wsensor properly replaced and <br />verified functional after tes ? <br />0 Yes Z Non NA <br />I <br />E] Yes 0 NoEjNA <br />I <br />0 Yes® No[]NA <br />F1 �s Z NoE) NA <br />E3 <br />Comments - (include information on repairs made prior to testing, and recommended follow-up for failed testsil <br />1 If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions inated with an <br />asterisk (*) is "NO" or "NX', the entire sump must be tested. T <br />
The URL can be used to link to this page
Your browser does not support the video tag.