My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1956 - 1972
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SPERRY
>
1051
>
4400 - Solid Waste Program
>
PR0504217
>
COMPLIANCE INFO_1956 - 1972
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2020 1:37:55 PM
Creation date
7/3/2020 10:35:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
1956 - 1972
RECORD_ID
PR0504217
PE
4430
FACILITY_ID
FA0004231
FACILITY_NAME
J M EAGLE (WS)
STREET_NUMBER
1051
STREET_NAME
SPERRY
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
17728039
CURRENT_STATUS
02
SITE_LOCATION
1051 SPERRY RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
CField
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4430_PR0504217_1051 SPERRY_1956-1972.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 2 <br />5. FEATURES <br />The following items are to be located and configured according to the drawings <br />2-188-49 2-189-5 and 2-190-4. <br />A. One access door for cleaning 36" high by 24" wide opening outward. <br />B. Top safety railing of CAL-OSHA approved design. <br />C. Steel baffle mounting bolt lugs as shown in drawing 2-190-4. <br />D. Bolted pipe flanges. <br />(1) 6 inch pipe, 3 locations. All three flanged on outside <br />end. One at the 4'-9" elevation is flanged on the inside end. <br />(2) 111 inch pipe, 1 location, flanged on both inside and outside <br />ends. <br />All flanges located 8 inches from tank wall. All exterior <br />flanges will have closing plates installed for the leak test. <br />s <br />E. Three 10-inch diameter deck openings with suitable support structure <br />for agitators equally spaced on a 14-foot diameter circle. <br />(See Dwg. 2-189-5). <br />F. Two hinged visual inspection hatches in roof, 18-24 inches in diameter. <br />G. Fixed roof access ladder of CAL-OSHA approved design. <br />H. One 10-inch diameter deck opening. <br />I. Tank to be set upon a 6--inch layer of crushed rock. Rock to be layed <br />on present concrete slab and retained by a steel ring. Resulting slope <br />of tank floor and deviation of walls from vertical not to exceed 1 in 100. <br />6. FINISH <br />Interior: Including primer, a three.layer white epoxy coating on all <br />interior parts. <br />Exterior: Primer = 1 coat Sherwin Williams KROMIX E41-N1 or.equal. <br />Paint = 1 coat Sherwin Williams Metalastic II non-chalking <br />white B53 W1O or equal. <br />