Laserfiche WebLink
Permit Unit Requirements for N-339-17-7 (continued) Page 2 of 6 <br /> 14. The flare shall be equipped with a temperature indicator and recorder that measures and records the operating <br /> temperature. The temperature indicator and recorder must operate continuously. [District NSR Rule] Federally <br /> Enforceable Through Title V Permit <br /> 15. The enclosed flare shall be equipped with automatic dampers,an automatic shutdown device, and a flame arrester. <br /> [District NSR Rule]Federally Enforceable Through Title V Permit <br /> 16. The enclosed flare shall be equipped with an LPG or natural gas fired pilot. [District NSR Rule]Federally Enforceable <br /> Through Title V Permit <br /> 17. Source testing on the flare shall be performed to demonstrate compliance with the NOx and CO limits, and the VOC <br /> destruction efficiency of 98%as required by this permit shall be conducted annually. [District NSR Rule] Federally <br /> Enforceable Through Title V Permit <br /> 18. Source testing for NOx shall be conducted using CARB Method 7 or Method 20. [District Rule 1081] Federally <br /> Enforceable Through Title V Permit <br /> 19. Source testing for CO shall be conducted using EPA Method 10 or IOB,CARB Methods 1 through 5 with 10, or <br /> CARB Method 100. [District Rule 1081]Federally Enforceable Through Title V Permit <br /> 20. VOC emissions shall be measured by EPA Method 18 or 25. [District Rule 1081] Federally Enforceable Through Title <br /> V Permit <br /> 21. H2S concentration of the influent landfill gas to the flare shall not exceed 46.9 ppmv. [District NSR Rule]Federally <br /> Enforceable Through Title V Permit <br /> 22. Gas combusted in the flare shall be tested for H2S content on a quarterly basis using draeger tubes. If compliance is <br /> shown for two consecutive quarters,the testing frequency may be changed to annual. Quarterly testing shall resume if <br /> any annual test shows noncompliance. [District Rule 1081]Federally Enforceable Through Title V Permit <br /> 23. Carbon canister on condensate storage tank vent shall be inspected monthly for breakthrough with a District-approved <br /> portable analyzer. [District NSR Rule]Federally Enforceable Through Title V Permit <br /> 24. Upon receiving an approved plan for closure, or partial closure,the operator shall modify this operating permit to <br /> comply with the requirements of District Rule 4642, [District Rule 4642,3.2 and 4.1.1]Federally Enforceable Through <br /> Title V Permit <br /> 25. The gas collection system shall be operated in such a manner that the surface emissions testing of the landfill shows <br /> the concentrations of total organic compounds(measured as methane)do not exceed 1,000 ppmv at any point on the <br /> surface of the solid waste disposal site or along the gas transfer path of the gas collection system. Sampling ports shall <br /> be installed on each well head. [District NSR Rule] Federally Enforceable Through Title V Permit <br /> 26. Gas collection system shall be operated in a manner which maximizes the amount of landfill gas extracted while <br /> preventing overdraw that can cause fires or damage the gas collection system. [District NSR Rule] Federally <br /> Enforceable Through Title V Permit <br /> 27. During maintenance of the gas collection system or incineration device,emissions of landfill gas shall be minimized <br /> during shutdown. [District NSR Rule] Federally Enforceable Through Title V Permit <br /> 28. Maintenance is defined as work performed on a gas collection system and/or control device in order to ensure <br /> continued compliance with District rules,regulations,and/or Permits to Operate,and to prevent its failure or <br /> malfunction. [District NSR Rule] Federally Enforceable Through Title V Permit <br /> 29. The gas collection system shall be operated such that the concentration of total organic compounds(as CH4)shall not <br /> exceed 1,000 ppmv at any point along the gas transfer path of the gas collection system. [District NSR Rule] Federally <br /> Enforceable Through Title V Permit <br /> 30. The entire gas collection system shall be inspected for leaks with a portable analyzer in accordance with EPA Method <br /> 21 at least quarterly.After four successful inspections,the frequency shall be annually.If a leak is detected,quarterly <br /> inspections shall resume. A leak is defined as a measurement in excess of 1,000 ppm(measured as methane)above <br /> background when measured at a distance of one(1)centimeter from the potential source. Leaks shall be repaired <br /> within 15 calendar days after it is detected. [District NSR Rule] Federally Enforceable Through Title V Permit <br /> PERMIT UNIT REQUIREMENTS CONTINUE ON NEXT PAGE <br /> These terns and conditions are part of the Facility-wide Permit to Operate. <br /> Facility Name: FORWARD,INC.LANDFILL <br /> Location: 9999 S.AUSTIN ROAD,MANTECA,CA 95336 <br /> N.330 17-7:Jw 14 2006 4:42PM••SIONC,= <br />