My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2001_2
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2001_2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:22 PM
Creation date
7/3/2020 10:48:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2001_2
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2001_2.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
853
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Two opposite specimens, each 1 -inch wide, shall be cut from the trial seam <br />sample by the Contractor and/or Liner Subcontractor. Under the observation of a <br />Geotechnical CQA Monitor, the specimens shall be tested by the Liner <br />Subcontractor in shear and peel using a field tensiometer to verify that seams <br />satisfy peel and tensile strength requirements. If a specimen fails, the seaming <br />equipment and seamer shall not be accepted and shall not be used for seaming <br />until the deficiencies are corrected and two consecutive successful full trial welds <br />are achieved. After completing a successful trial/nondestructive sample, the <br />Contractor and/or Liner Subcontractor shall cut a 2'x 2' remnant from the sample <br />and mark the welder number, date, time, ambient temperature, welder <br />temperature, and speed and submit it to the Geotechnical CQA Monitor -who -will <br />assign an identification number and enter the information on the non-destructive <br />sample form. <br />The results of field tests carried out on trial seams shall be documented by the <br />Geotechnical CQA Monitors. <br />General Seaming Procedure <br />Unless otherwise specified, the general seaming procedure to be used by the <br />Contractor and/or Liner Subcontractor shall be as follows: <br />All VFPE seams shall be overlapped a minimum of four (4) inches. <br />"Fishmouths" or wrinkles at the seam overlaps shall be cut along the ridge of <br />'the wrinkle in older to achieve a flat overlap. The cut "fishmouths" or <br />wrinkles shall be seamed and any portion where the overlap is inadequate <br />°shah then be -patched with -an oval orround-patchof the same VFPE trxtentting <br />a minimum of 6 inches beyond the cut in all directions. All corners of the <br />pat�ch-•shai-1,be r-ounded with -a 1 -inch mini rn-radius. <br />• Adjacent to anchor trenches, seaming shall extend up the panels a minimum <br />of 12-inches.,pastAhe crest -of the anchor.trench. <br />• All cross seams shall be offset at least two feet from the cross seam of the <br />adjacent panel and be extrusion or wedge welded where they intersect. <br />The Geotechnical CQA Monitors shall observe that the above seaming procedures <br />are followed, and shall inform the Construction Manager if they are not. <br />6.2.5 CONSTRUCTION TESTING <br />6.2.5.1 Nondestructive Seam Testing <br />The Contractor and/or Liner Subcontractor shall non-destructively test all field <br />seams over their full length using a vacuum test unit, spark detector, or an air <br />pressure test (for double wedge fusion seams only), as described below. The <br />purpose of nondestructive tests is to check the continuity of seams. It does not <br />-24- <br />CA2001-048\FINAL COVER_CQA.DOC\08/20/01 <br />Geologic Associates <br />
The URL can be used to link to this page
Your browser does not support the video tag.