My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2014_5
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2014_5
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2020 9:58:07 AM
Creation date
7/3/2020 10:57:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2014_5
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2014_5.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8. Placement of granular drainage materials on the geomembrane shall not <br /> proceed when the ambient temperature is less than 40 degrees F or more <br /> than 104 degrees F, unless approved by the QA/QC CONSULTANT. <br /> 9. Placement of granular drainage materials on the geomembrane shall be <br /> halted when wrinkling of the geomembrane becomes excessive enough, in <br /> the opinion of the QA/QC CONSULTANT, to damage the geomembrane. <br /> The EARTHWORK CONTRACTOR will not be compensated for any costs <br /> or delays resulting from this halt in Work and shall schedule granular <br /> drainage material placement at times when wrinkling of the geomembrane, <br /> in the opinion of the QA/QC CONSULTANT, is minimal. Approval by the <br /> QA/QC CONSULTANT of appropriate times for GDM placement does not <br /> absolve EARTHWORK CONTRACTOR of responsibility for repairing any <br /> geomembrane lining material damages during GDM placement, at <br /> EARTHWORK CONTRACTOR's sole expense. <br /> C. Compaction Requirements: Compact using a minimum of two passes of a low <br /> ground pressure dozer (see Section 3.12.13.5), unless otherwise approved by the <br /> QA/QC CONSULTANT or DESIGN ENGINEER prior to start of the Work. <br /> Approval does not absolve the EARTHWORK CONTRACTOR of <br /> responsibilities for damage to the underlying geomembrane lining, at the <br /> EARTHWORK CONTRACTOR's sole expense. <br /> D. Quality Control: <br /> 1. General: As the GDM is being placed, the QA/QC CONSULTANT will be <br /> monitoring the construction activities and soil properties. If tests conducted <br /> by the QA/QC CONSULTANT indicate that the GDM does not meet <br /> specified requirements, the EARTHWORK CONTRACTOR shall <br /> terminate material placement until corrective measures are taken. <br /> 2. GDM Acceptance: Final acceptance of the GDM will be based on all tests <br /> made on completed Work on material samples taken from the completed <br /> layer, on leak location testing and repair, and on thickness as determined by <br /> the top of Clay Liner and top of GDM surveys. Testing for final acceptance <br /> shall be performed by the QA/QC CONSULTANT in accordance with <br /> these Specifications and the CQA Manual. <br /> E. Protection: <br /> 1. Do not route construction traffic on top of GDM once material has been <br /> placed. <br /> 2. Constructed GDM shall be maintained to meet the requirements of this <br /> Specification until final completion and acceptance of the Work. This shall <br /> include all measures to prevent erosion. During seasonal or other extended <br /> shutdowns, all exposed surfaces shall be protected as detailed in Article 3.1 <br /> of this Section. In addition, the GDM shall be protected from any <br /> contamination that reduces the hydraulic conductivity. Any contaminated <br /> materials shall be removed and replaced at no cost to the OWNER. <br /> Forward Landfill WMU FU-14 <br /> 02300 22 EARTHWORK <br />