5.1.0 Leachate <br /> There is no monitoring and control system for leachate at HLSL because <br /> the landfill is unlined and leachate is not collected. <br /> 5.1.11) Landfill Gas Migration Monitoring <br /> 5.1.D.1 Monitoring Wells <br /> Offsite LFG migration at HLSL is monitored with 12 perimeter <br /> landfill gas migration monitoring wells, each of which is a "nested" <br /> set of three probes Installed at varying depths within the well <br /> (Figure 2). These wells are spaced less than 1000 feet apart to <br /> adequately monitor for LFG off-site migration. This system has <br /> been accepted for the purpose of monitoring off-site migration <br /> since closure of HLSL. <br /> 5.1.D.2 Monitoring Method and Procedure <br /> Offsite migration is monitored according to HLSL's revised Landfill <br /> Gas Monitoring Plan (Appendix B). <br /> 5.1.D.3 Monitoring Frequency <br /> All migration monitoring wells are monitored in accordance with <br /> CCR Title 27 Section 20933. <br /> 5.1.E Additional Soil Gas Monitoring <br /> Select soil perimeter LFG migration monitoring well probes (GW-9 <br /> Intermediate and GW-10-Deep) are sampled semi-annually for <br /> concentration of volatile organic compounds (VOCs) in accordance <br /> with the WDR's. <br /> Postclosure Maintenance Plan San Joaquin County <br /> Harney Lane Sanitary Landfill 5 Department of Public Works <br /> Revised July 30,2009 Solid Waste Division <br />