My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_1992-1993
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOVELACE
>
2323
>
4400 - Solid Waste Program
>
PR0440013
>
ARCHIVED REPORTS_1992-1993
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2021 3:09:36 PM
Creation date
7/3/2020 11:15:31 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
1992-1993
RECORD_ID
PR0440013
PE
4445
FACILITY_ID
FA0001434
FACILITY_NAME
LOVELACE TRANSFER STATION
STREET_NUMBER
2323
STREET_NAME
LOVELACE
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20406020
CURRENT_STATUS
01
SITE_LOCATION
2323 LOVELACE RD
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4445_PR0440013_2323 LOVELACE_1992-1993.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
267
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
is elev. 10.0, based on 1986 County Flood Control data. The sump system in the <br /> tunnel will remove surface flows and seepage. <br /> Water in contact with waste: <br /> The County may occasionally wash down the tipping/sorting floor areas in the <br /> Transfer Building. For this reason the tipping floor is designed with floor drains (See <br /> Drawing RSI-3) which drain to a small sump in the transfer tunnel area (See Drawing <br /> RSI-6). These flows will be pumped up to a storage tank (2,00 gallons) for off-site <br /> disposal, as needed. The approximate location for the waste water storage tank is <br /> west of the building in the fueling area (this will provide for easy access for emptying <br /> the tank). Conceptual layout for this system is shown on Drawing RSI-7. <br /> f. Utilities Plan <br /> Utilities required for the project are shown on the Conceptual Utilities Plan, Drawing <br /> RSI-8. Design criteria and a brief description follow. <br /> • Storm drains stem - County Provement Standards (Sept. 1991 <br /> ) <br /> • Sanitary sewer lines and leach field - County Ordinance 549. Preliminary <br /> design sizing of the leach field is in Appendix D. Final Plan approvals by the <br /> EHD are anticipated to be processed through the approval process of the <br /> County Department of Planning and Building Inspection. <br /> • Water supply lines - County Improvement Standards (Sept. 1991), as <br /> applicable <br /> • Fire service lines, hydrants, pump house and storage tank - County <br /> Improvement Standards (Sept. 1991), and requirements of Manteca Lathrop <br /> Fire District <br /> • Electrical supply - The electric utility, Pacific Gas and Electric, will provide <br /> underground service from a utility pole along the north side of Lovelace Road <br /> to a utility supplied pad mounted transformer. Twenty percent design layout <br /> drawings will be submitted to PG&E for review. A 480/277 volt distribution <br /> switchboard will be mounted inside the Transfer Building and fed from the <br /> utility's transformer. A 480 volt three-phase underground feeder will be <br /> provided from the main switchboard to the: <br /> - Scalehouse <br /> O&M Building <br /> Firewater Pumphouse <br /> - Sump pump lift stations <br /> - Well <br /> Telephone service will be provided for the Transfer Building, scalehouse, <br /> O&M Building, fire pumphouse, and a pay phone will be provided outside the <br /> O&M Building. <br /> • Pole mounted lighting - The following exterior locations will be used for pole <br /> 07549001.012 24 September 23,1993 <br />
The URL can be used to link to this page
Your browser does not support the video tag.