My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2014
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0517379
>
ARCHIVED REPORTS_2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2020 11:24:49 AM
Creation date
7/3/2020 11:19:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2014
RECORD_ID
PR0517379
PE
4466
FACILITY_ID
FA0007101
FACILITY_NAME
FORWARD INC LANDFILL
STREET_NUMBER
9999
Direction
S
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106003
CURRENT_STATUS
02
SITE_LOCATION
9999 S AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4466_PR0517379_9999 S AUSTIN_2014.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
181
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1. The polyethylene resin shall meet or exceed the requirements of <br /> ASTM D3350 for PE 3408 material with a cell classification of 345464C, <br /> or better and a material classification of III C5 P34. Driscopipe of <br /> Richardson, TX, Model Driscopipe 1000 pipe and Plexco of Benseville, IL, <br /> Model Plexco PE 3408 Industrial Piping meet these regirements. <br /> 2. The polyethylene compound shall be suitably protected against degradation <br /> by ultraviolet light by means of carbon black, well dispersed by <br /> precompounding in a concentration of not less than 2 percent. <br /> 3. The maximum allowable hoop stress shall be 800 psi at 73.4° F. <br /> 4. The pipe manufacturer shall be listed with the Plastic Pipe Institute as <br /> meeting the recipe and mixing requirements of the resin manufacturer for <br /> the resin used to manufacture the pipe for this project. <br /> 5. Pipe sizes shall conform to ASTM F714. <br /> 6. The pipe shall conform to the following schedule: <br /> Piping System and/or <br /> Nominal Pipe Location SDR <br /> Size <br /> 18 inch Solid and Perforated 11 <br /> Leachate Riser Pipe <br /> 24 inch Pond Inlet Pipe and Culvert 11 <br /> 30 inch Pond Inlet Pipe and Culvert 11 <br /> 7. Perforate required portions of 18-inch pipe with 1/2-inch diameter holes <br /> drilled on thirds, spaced 6-inches on center. <br /> 2.2 FITTINGS <br /> A. Polyethylene fittings shall be fabricated from polyethylene pipe for sizes 8-inch <br /> and larger, by means of thermal butt-fusion. The ends of the fabricated fittings <br /> shall not be trimmed to match the pipe section to which they are going to be <br /> joined. All polyethylene fittings shall have the same or higher pressure rating as <br /> the pipe when installed in accordance with the latest technical specifications. <br /> 2.3 JOINTS <br /> A. Thermal butt-fusion, except where connecting to unions, valves, and equipment <br /> with threaded connections that may require future disassembly. <br /> 2.4 ONE-WAY VALVE <br /> A. Submit proposed one-way valve to Design Engineer for review and approval. <br /> Forward Compost Facility Stormwater Improvements <br /> 02535 2 PIPES <br />