LFR Levine-Fricke <br /> I WOO <br /> SVOCs were not detected above laboratory reporting limits in samples collected from <br /> wells MW-1 through MW-5 during the second through fourth quarters of 2003. <br /> Metals <br /> Metals were not detected above MCLs in samples collected from wells MW-1 through <br /> MW-5 during the second through fourth quarters of 2003. The metal concentrations <br /> reported for monitoring well samples are shown on Figures 6 through 8. <br /> Based on a comparison of groundwater quality data between the downgradient wells <br /> and the upgradient well (MW-3) located at the Site during 2003, the tire fire does not <br /> appear to have affected groundwater quality beneath the Site. Zinc was detected above <br /> j the reporting limit in groundwater samples collected from two of the five wells during <br /> I the second quarter 2003 at concentrations ranging from 0.0053 mg/l (MW-5) to 0.0055 <br /> mg/l (MW-4). Zinc was not reported above the reporting limit in groundwater samples <br /> collected during the third quarter 2003. Zinc was detected above the reporting limit in <br /> samples collected from two of the five wells during the fourth quarter 2003 at <br /> concentrations ranging from 0.0054 mg/l (MW-2) to 0.0057 mg/1 (MW-4). The <br /> reported concentrations of zinc in the groundwater samples throughout the Site are <br /> generally consistent with the concentrations detected in the groundwater samples <br /> collected from the background well (MW-3). Additionally, lead, another potential <br /> constituent of concern, was not detected in groundwater samples collected from the <br /> five wells during the second through fourth quarters of 2003. <br /> Field Parameters <br /> Values of pH in groundwater samples collected from site monitoring wells during 2003 <br /> were generally consistent. The values were neutral and ranged from 7.2 pH units <br /> (MW-3, second quarter) to 8.14 pH units (MW-2, third quarter). <br /> Concentrations of TDS in the groundwater samples collected from site wells ranged <br /> from 623 mg/l in the samples collected from well MW-2 during the second and third <br /> quarter to 1,180 mg/l in the sample collected from MW-3 during the fourth quarter. <br /> The secondary MCL for TDS is 500 mg/l. The samples collected from the upgradient <br /> well (MW-3) contain higher concentrations of TDS compared to the downgradient site <br /> wells, suggesting that the TDS concentrations detected are likely representative of <br /> J background conditions. <br /> Turbidity concentrations measured in the field ranged from 89 NTU in the sample <br /> collected from MW-4 during the third quarter to 5,300 NTU in the samples collected <br /> from wells MW-5 during the second quarter. <br /> 1 <br /> i <br /> i <br /> t <br /> 'ITFS QMR Q4-03.F1NAL:JEE Page 7 <br />