My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
PR0535342
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
29425
>
4700 - Waste Tire Program
>
PR0535342
>
PR0535342
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/29/2020 5:32:38 PM
Creation date
7/22/2020 8:36:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4700 - Waste Tire Program
RECORD_ID
PR0535342
PE
4740
FACILITY_ID
FA0020390
FACILITY_NAME
RENEWED RESOURCES CORP
STREET_NUMBER
29425
Direction
S
STREET_NAME
MACARTHUR
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25312026
CURRENT_STATUS
02
SITE_LOCATION
29425 S MACARTHUR RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10992
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TEL No . Aug 27 ,98 10 :28 Ido .011 P .03 <br /> t <br /> 4 )RM FIRE CODE 1994 UNIFORM FIRE CODE 1103.3.3.4-1104,2 <br /> f <br /> EXCEPTION: when the aggregate arca of murals.s gm ur similar decorative objects occupies leis that, <br /> be orderly. 10 percent of the floor or wall area,this requirement may be waived by the chief. <br /> 3, Theater.motion picture and television stage settings with or without horizontal projections j <br /> Tm)or more below the and simulated caves or caverns shall have a maximum heat release rate of 100 kilowatts when <br /> tested in accordance with nat,unally recogniccd standards.See Article 9U,Standard u.1.I5. <br /> lead deflectors in span- 1103,3.3.5 Nonfoam plastics. Plastic materials other than foam plastics shall be flame resistant <br /> or shall be rendered flame resistant by treating with a flame-retardant coating. <br /> t enc losui 1103.3.3.6 Maintenance of flame-resistant treatments. Treatments used to render material.,, <br /> boiler rooms.mechan- flame resistant shall be renewed as often as necessary to maintain the materials'flame resistance in <br /> accordance with Section 1103.3.3. <br /> and concealed spaces 1103.3.4 Atrium furnishings. <br /> de as required for one, 1103.3.4.1 Potential heat. Potential heat of combestlble fumishings and decorative materials <br /> lar are self-closirg and within atna shall not exceed 9,000 Btu per pound(20 934 J/g)when located within an area that is <br /> ,h(44.5 mm)in thick- more than 20 feet(6096 mm)below ceiling-level sprinklers. <br /> 1103.3.4.1 Decorative materials. Decorative material in atria shall be noncombustible,flame re. <br /> sistant or treated with a flame retardant. <br /> Cued to motorcycles. 1103.3.5 Outside storage. <br /> stored,operated or re• 1103.3.3.1 Location. Outside storage of combustible materials shall not be located within 10 feet <br /> (3048 mm)of a property tine. <br /> with the Building CWc, EXCEPTIONS: 1. The separation distance is allowed to be reduced to 3 feet(914 mm)for swragc not ,I <br /> exceeding b feet(1$29 mm)in height. <br /> cation when the pres- 1 The separation distance is allowed to be reduecd when the chief determines that no hazard to the adjoin• <br /> ing pmpcny exists. <br /> 1103.3.5.2 Storage beneath buildings and structures. Combustible material shall not be stored <br /> beneath a building or structure. <br /> 1103.3.5.3 Storage beneath overhead projections from buildings. Conlbus[ible materials <br /> otip 11 and M whole- stored or displayed outside of buildings that are protected by automatic sprinklers shall not be <br /> I I Occupancies shall stored or displayed under unsprinklered eaves.canopies or other pro)ectlons or overhangs. <br /> 1103.3.5.4 Height. Storage in the open shall not exceed 20 feet(6x)96 flim)in height. , <br /> mitamed in an approved 1103.16 Outside storage of tires. '1 <br /> 1103.3.6.1 General. Outside tire storage shall be in accordance with Scctivn 1103.3.6. <br /> )y the chlet 1103.3.6.2 individual piles. Tires shall be restricted to individual piles not exceeding 5,000 <br /> ated and maintained square feet(464.5 m=)of continuous area.Piles shall not exceed 50,000 cubic feet(1415.8 m3)in <br /> :90,Standard n.2.3. volume or I0 feet(3048 mm)in height. <br /> ricss shall be treated 1103.3.6.3 Separation. A clear space of at least 40 feet(12 192 nim)shall be provided between <br /> irds.See Article 90, piles.The clear space shall not contain flammable or combustible material or vegetation.Tire stor- <br /> age shall not be located within 10 feet(3048 mm)of any property line or building and shall not ex- <br /> teed 6 feet(1829 moll in height when within 20 feet(6096 mm)of any property line or building <br /> cs shall be in actor- ng <br /> 1 <br /> i <br /> 00 kilowatts when SECTION 1104—PARADE FLOATS � <br /> ndard u.1.15. 1104.1 Decorative Material. Decorative material on parade floats shall be noncombustible or I <br /> signs,shall have a flame retardant. <br /> ;tonally recognized 1104.2 Fire Protection. Motorized parade floats and towing apparatus shall be provided with a <br /> minimum 2•A, 10-B:C-rated portable fire extinguisher readily accessible to the operator. <br /> 149 <br />
The URL can be used to link to this page
Your browser does not support the video tag.