Laserfiche WebLink
Installation Guide; ResrdentiafAdvanTex® Syste►ns <br /> r�='�fnr VenCQm�Co►�irol�Pan�lj <br /> . ..:lig,.,. <br /> VeriComm® (VCOM)telemetry-enabled panels are used for Serial Port RS232 Power Comer <br /> remote monitoring and control ofAdvanTex pumping operations. Modern Input Fuse <br /> . Act3yitY <br /> Fault conditions are automatically reported to the VeriComm Test Button <br /> Monitoring System,making the system virtually invisible to <br /> the homeowner. However,if fault conditions are not responded <br /> to,or if the system cannot communicate with the VeriComm <br /> Monitoring System,then local alarms may be activated. o,si <br /> Follow the procedures,below,to verify proper installation of the ; <br /> VeriComm panel. m <br /> v a. <br /> NOTE: For more detailed procedures speck to each panel <br /> model, refer to the documentation that comes with the panel. 10 •�s.. o*� ea°� <br /> nlgi«ai l (s� <br /> Step 1: Familiarize yourself with the components of the telemetry D W S(4) <br /> control board Friona;laic Power LED <br /> Output FM <br /> Step 2: Make sure the panel has been completely and correctly <br /> installed and verify that the circuit breakers are in the"On"position. <br /> Also check the controller status.The"Power LED'located on the 0 <br /> control board will be: <br /> • Blinking,which indicates the controller is operating normally,or <br /> • Off(when power is applied),which indicates a possible problem with QD Highfwater alarm <br /> the input fuse on the PC board; ® Middle flat <br /> r the main fuse located inside the panel, Ovarrfde timer <br /> the controls circuit breaker located inside the panel;or <br /> the incoming line voltage. <br /> Step 3: To enable Test Mode,hold the"Push-To-Silence" <br /> m float <br /> button on the front of the panel until the audible alarm sounds Law <br /> (approximately 15 seconds). redundant off <br /> • The appropriate digital input should be illuminated when the button is <br /> held in. <br /> • When the audible alarm sounds to indicate that the panel is in Test <br /> tether <br /> Mode,release the button. <br /> While in Test Mode,the panel will operate in the following <br /> manner: <br /> • The Call Home function is disabled, <br /> • Local audible and visual alarms are activated as alarm conditions <br /> occur, <br /> • System Data Logs are suspended;and <br /> • Timer cycles are shortened. <br /> i <br /> Step 4: Familiarize yourself with the floats on the system. <br /> NEM-ATX-AX-1 0 2004 erenco Systems*Inc. <br /> Rev 3.1.ow <br />