My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
401
>
4200 – Liquid Waste Program
>
PR0526172
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/3/2020 7:50:28 PM
Creation date
8/5/2020 10:00:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200 – Liquid Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0526172
PE
4242
FACILITY_ID
FA0017710
FACILITY_NAME
ANKA NORTHSTAR
STREET_NUMBER
401
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
MANTECA
Zip
95336
APN
24130052
CURRENT_STATUS
01
SITE_LOCATION
401 S AIRPORT WAY
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\4200 - Liquid Waste\A\AIRPORT WAY\401\PR0526172\INSPECT CORRESPOND.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
flSta tlo#' G tE andalAdvanFe :Systems <br /> Y rv- Step 5: Verify that the pump is submerged in water before <br /> = continuing. If the bottom float drops,the alarm should sound <br /> - Press down the spring-loaded"MAN/AUTO"switch located <br /> inside the panel. The pump should immediately activate, For <br /> verification,the appropriate digital input should illuminate, <br /> indicating that the auxiliary contact is on. <br /> Measure the voltage and amperage of the pump. <br /> a)Measure the voltage at the pump terminals in the panel while the <br /> - pump is running.A low voltage condition could indicate that the site <br /> Wring is improperly sized. <br /> b1 Using a loop ammeter,place the ammeter clamp around the loop of <br /> wire located above the pump circuit breaker. The amperage should <br /> be within the specifications of the pump. <br /> . Y. Step 6: Refer to the control panel documentation to test the <br /> floats that activateideactivate the pump.To perform the float <br /> _ test,make sure there is a sufficient amount of liquid in the tank. <br /> If there is not enough liquid in the tank,turn the pump circuit <br /> breaker off. <br /> —=- - Step 7: Press and release the"Tush-To-Silence"button 15 times <br /> within a one-minute period. This instructs the panel to call the <br /> VeriComm Monitoring System. <br /> '� ` • A red LED("Modem Activity"component}should illuminate, <br /> indicating that the controller has established communication with the <br /> host (This may take a few minutes.) <br /> -- • Once the communication session has ended,the modem will <br /> automatically disconnect <br /> • If the LED does not illuminate within the specified time, verify that the <br /> phone line has a dial tnne. This can be done by hooking up a phone <br /> to the line that is going into the panel. <br /> Step S: The panel will automatically disable Test Mode and <br /> return to normal operation after 30 minutes. To disable Test <br /> « .; Mode manually, hold the "Push-To-Silence"button on the front <br /> of the panel until the audible alarm sounds(approximately 15 <br /> - seconds). The appropriate digital input should be illuminated <br /> when the"Push-To-Silence"button is held in. When the audible <br /> alarm sounds to indicate that the panel is no longer in Test Mode, <br /> release the button. <br /> Q1 2004 Otancs Systems•Inc. N11114-AMAX-11 <br /> Raw 11,044E <br />