1630A215-Mar2008 1730A215-Mar2008 <br />D. GAS CONNECTION: The gas supply (service) line must be the same size or greater than the inlet line of the appliance. THE GAS <br /> SUPPLY LINES MUST BE SIZED TO ACCOMMODATE ALL THE GAS-FIRED EQUIPMENT THAT MAY BE CONNECTED TO <br /> THAT SUPPLY. Refer to the Inlet Gas Line Sizing and Inlet Gas Requirements Tables. <br /> WARNING <br /> Sealant used on all pipe joints must be resistive to butane and propane gas. <br /> 1. Manual shut off valve: The supplier-installed valve must be installed in the gas service line ahead of the appliance and in a posi- <br /> tion where it can be reached quickly in the event of an emergency. <br /> 2. Pressure regulator: All commercial cooking equipment must have a pressure regulator on the incoming service line for safe and <br /> efficient operation, because service pressure may fluctuate with local demand. External regulators are not required on this fryer, as <br /> that function is performed by a combination gas control valve, however if the incoming pressure is in excess of 1⁄2 psig, a step-down <br /> regulator will be required. <br /> 3. Natural gas: Natural gas fryers require 7" (178mm) water column (W.C.) “inlet” pressure to the fryer’s combination gas control <br /> valve for proper operation, when all gas units are operating simultaneously. Butane and Propane gas fryers require 14" (56mm) <br /> water column (W.C.) “inlet” pressure to the fryer’s combination gas control valve for proper operation, when all gas units are oper- <br /> ating simultaneously. This“inlet” pressure MUST be checked with a manometer PRIOR to placing the fryer in operation. <br />WARNING: IF THE “INLET” GAS PRESSURE AT THE FRYER’S COMBINATION GAS CONTROL VALVE EXCEEDS 1⁄2 LB/IN2 (.035 <br />KG/CM2) OR APPROXIMATELY 14" (356 mm) W.C., AN EXTERNAL REGULATOR MAY BE NEEDED TO PREVENT DAMAGE TO <br />THE COMBINATION GAS VALVE AND VOIDING OF THE WARRANTY. FAILURE TO CORRECT THIS CONDITION COULD RESULT <br />IN EXPLOSION OR FIRE. <br /> 4. Combination gas control valve: The correct combination gas control valve and orifice is installed at the factory for BUTANE, <br /> NATURAL, and PROPANE units based on each Purchase Order. This valve should be CHECKED/ADJUSTED by qualified <br /> service personnel using proper test equipment for the following “OUTLET” gas pressure PRIOR to start-up of a fryer. <br /> NATURAL GAS FRYERS 4" (102mm) W.C. BUTANE/PROPANE FRYERS 10" (254mm) W.C. <br /> 5. Rigid connections: Check any installer-supplied intake pipe(s) visually and/or blow them out with compressed air to clear dirt <br /> particles, threading chips or any other foreign matter before connecting to the service line as these particles may clog the orifice <br /> when gas pressure is applied. All connections must be tested with a soapy solution before lighting the fryer. <br /> DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS! Putting an open flame beside a new connection is not only <br /> dangerous, but will often miss small leaks that a soapy solution would find. <br /> 6. Flexible Couplings, Connectors: The installation is to be made with a connector that (1) complies with the Standard for <br /> Connectors for Movable Gas Appliances, ANSI Z21.69 (CAN/CGA-6.16), and a quick-disconnect device that complies with <br /> the Standard for Quick-Dis-connect Devices for Use With Gas Fuel, ANSI Z21.41 (CAN1-6.9) (2) adequate means must be <br /> provided to limit the movement of the fryer without depending on the connector and the quick-disconnect device or its <br /> associated piping to limit the movement and (3) the location(s) where the restraining mechanism may be attached to the fryer <br /> shall be specified.DOMESTIC CONNECTORS ARE NOT SUITABLE!!! <br /> 7. Fryer Service: The fryer is equipped with swivel casters. To service the fryer: <br /> a) Turn “OFF” gas supply at the supply source. <br /> b) Disconnect the flexible gas line quick-disconnect <br /> c) Disconnect restraint mechanism and roll the fryer out for rear service access. <br /> d) When the fryer is repositioned, be sure to reconnect the restraint mechanism and level the fryer. <br />E. ELECTRICAL CONNECTION: The MAXIMUM current draw per vat at Initial Start-up or during a Warm-up Cycle will be 3 <br /> Amperes at 120 Volts. Refer to the wiring diagram located inside the service access door of the fryer for internal electrical connec- <br /> tions. <br /> WARNING <br />(Electrical Grounding Instructions) <br />This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and <br />should be plugged directly into a properly grounded three-prong receptacle. Do not cut, remove, or otherwise <br />bypass the grounding prong on this plug!