My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ACAMPO
>
4600
>
1600 - Food Program
>
PR0161846
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/2/2022 4:10:27 PM
Creation date
8/18/2020 9:17:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0161846
PE
1632
FACILITY_ID
FA0000244
FACILITY_NAME
LODI USD-HOUSTON SCHOOL
STREET_NUMBER
4600
Direction
E
STREET_NAME
ACAMPO
STREET_TYPE
RD
City
ACAMPO
Zip
95220
APN
01731001
CURRENT_STATUS
01
SITE_LOCATION
4600 E ACAMPO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
142
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SCHEDULE <br />ELEC. <br />NO. <br />ITEM <br />NO.DESCRIPTION QTY.VOLT.PH REMARKS <br />DRAW <br />AMPS.WATT <br />LOAD OUTLET <br />HEIGHTHP <br />NEMA <br />PLUGDIRECTNOTE(S) <br />WALK-IN REFRIGERATION ELECTRICAL (MINIMUM REQUIREMENTS UNLESS NOTED OTHERWISE)ELECTRICAL KEYNOTES: <br />1. - <br />2. - <br />3. - <br />4. -THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONDUIT AND WIRING NECESSARY FOR A COMPLETE AND OPERABLE <br />SYSTEM WITH ALL CONDUIT IN SO FAR AS POSSIBLE MOUNTED ON THE EXTERIOR CEILING OF THE WALK-IN ASSEMBLY. <br />PENETRATIONS AND ESCUTCHEON PLATES SHALL BE FURNISHED AND INSTALLED BY THE FOOD SERVICE CONTRACTOR. <br />FOOD SERVICE EQUIPMENT CONTRACTOR IS RESPONSIBLE FOR SEALING THE INSIDE OF CONDUITS WHICH PENETRATE <br />THE CEILING OR WALL. <br />THE ELECTRICAL CONTRACTOR SHALL INTER WIRE THE TIME CLOCK ON THE CONDENSING UNIT TO THE DEFROST RELAY <br />ON THE UNIT EVAPORATOR LOCATED IN THE FREEZER COMPARTMENT. <br />THE FOOD SERVICE EQUIPMENT CONTRACTOR SHALL INSTALL THE PRESSURE RELIEF PORT, DOOR HEATERS, DRAIN LINE <br />HEATERS AND TEMPERATURE ALARM SYSTEM. INTER WIRING AND FINAL CONNECTIONS BY THE ELECTRICAL CONTRACTOR. <br />THE ELECTRICAL CONTRACTOR SHALL INSTALL AND INTER WIRE LIGHT SWITCHES AND FIXTURES REQUIRED FOR THE <br />FOOD SERVICE EQUIPMENT AND MAKE FINAL CONNECTIONS. <br />DRAIN LINE HEATER CONNECTED TO COIL. F.S.E.C TO PROVIDE AND CONNECT TO COIL <br />1 <br />3 <br />4 <br />5 <br />6 <br />2 <br />12OV/1 PHASE FOR LIGHTS TO ONE PRE-WIRED CONN. POINT ON HOOD FOR LIGHTS PRE-WIRED BY FACTORY. <br />E.C TO CONNECT HOOD LIGHTS AT (2) HOODS <br />ELECTRICAL CONTRACTOR TO PROVIDE INTERLOCK WIRING FROM FIRE PROTECTION SYSTEMS TO ELEC. SHUNT TRIP <br />BREAKERS. <br />ELECTRICAL CONTRACTOR TO PROVIDE EMPTY FLUSH MT'D. OCTAGONAL BOX @ +48" AFF. W/ EMPTY CONDUIT TO +2" <br />ABOVE CEILING. <br />INTERCONNECT TEMP ALARM WITH MECHANICAL ALARM SYSTEM VERIFY WITH ELECTRICAL <br />1EA.120 1 9 +86 PROVIDE J-BOX IN WALL <br />INSTALL DOOR LIMIT SWITCH FOR INSTANT ON/OFF SWITCH BY F.S.E.C SEE DETAIL ---XAIR CURTAINE1 <br />E2 <br />E3 <br />E4 <br />E5 <br />E6 <br />E7 <br />E8 <br />E9 <br />E10 <br />E11 <br />E12 <br />E13 <br />E14 <br />E15 <br />E16 <br />E17 <br />E18 <br />E19 <br />E20 <br />EXHAUST HOOD ELECTRICAL SCHEDULE <br />ELEC. <br />EH1 <br />NO. <br />ITEM <br />NO.DESCRIPTION QTY.VOLT.PH REMARKS <br />DRAW <br />AMPS.WATT <br />LOAD OUTLET <br />HEIGHTHP <br />NEMA <br />PLUGDIRECTNOTE(S) <br />1EA.120 1 15 +86---XEXHAUST HOOD 5 -(ENERGY MANAGEMENT SYSTEM LIGHTS) <br />PROVIDE J-BOX IN WALL CONNECT TO UNIT ELECTRICAL CONNECTION <br />(REFER TO FS5.2 FOR ELECTRICAL CONNECTION)3 <br />4 <br />1 -B/ FS8.2 <br />1EA.120 1 2.0 -+88"WALK-IN REFRIGERATOR (BOX)---X <br />1EA.115 1 1.8 -+74"CONNECT TO UNIT ELECTRICAL CONNECTION AT COIL INSIDE WALK-IN REFRIGERATOR. <br />SEE DETAIL I/FS7.1WALK-IN REFRIGERATOR (COIL)---X <br />(2) 39W LED CLG. MT'D. LIGHT FIXTURES (1) 11.5W LED LIGHT FIXTURE AT DOOR. <br />CONTRACTOR TO PROVIDE ALL INTERCONNECTIONS.1 <br />2 <br />2 <br />1EA.208 1 12.8 -+74"CONNECT TO UNIT ELECTRICAL CONNECTION AT COIL INSIDE WALK-IN FREEZER. <br />SEE DETAIL I/FS7.1---XWALK-IN FREEZER (COIL)2 <br />3 1EA.120 1 5.0 -+88"---XWALK-IN FREEZER (BOX)(1) 39W LED CLG. MT'D. LIGHT FIXTURES (1) 11.5W LED LIGHT FIXTURE AT DOOR. <br />250W DOOR HEATER, 20W P.R.P, 100W WINDOW HEATER EC. TO PROVIDE ALL INTERCONNECTIONS.1 <br />3 <br />5.1 1EA.1 4-20 +104" <br />1EA.55.1 FIRE SYSTEM (REMOTE PULL STATION) +48" <br />120 <br />-- <br />X <br />X <br />--- <br />-----PROVIDE EMPTY FLUSH MT'D. OCTAGONAL BOX <br />(REMOTE PULL) SEE MANUAL PULL DETAIL 2/FS5.3 <br />120V/1-20AMP @ ANSUL CONTROL <br />FIRE SYSTEM <br />AT ANSUL CONTROL AUTOMAN PANEL <br />PROVIDE J-BOX IN WALL, CONNECT TO UNIT ELECTRICAL CONNECTION <br />TILT SKILLET8 1EA.1 -9.0 +25"120 X ---4PROVIDE J-BOX IN WALL, CONNECT TO UNIT ELECTRICAL CONNECTION <br />9 STEAMER, CONVECTION (2) COMPARTMENT 2EA 120 1 -X 5-15P 1.0 -+12" <br />PROVIDE DUPLEX RECEPTACLE <br />UNIT PROVIDED WITH 6' CORD (NEMA 5-15P) <br />+30"4 <br />CONVECTION OVEN DOUBLE STACK10 2EA.120 1 6.0--+24" <br />+66"45-15P PROVIDE DUPLEX RECEPTACLE FLUSH WITH STAINLESS STEEL WALL LINING <br />UNIT PROVIDED WITH CORD (NEMA 5-15P)X- <br />CONVECTION OVEN DOUBLE STACK10.1 2EA.120 1 7.2--+24" <br />+66"5-15P PROVIDE DUPLEX RECEPTACLE FLUSH WITH STAINLESS STEEL WALL LINING <br />UNIT PROVIDED WITH CORD (NEMA 5-15P)X- <br />MOBILE WARMING CABINET 3EA.120 1 16.7 +68"5-20P PROVIDE DUPLEX RECEPTACLE <br />UNIT PROVIDED WITH 10' CORD (NEMA 5-15P)X--13 <br />MIXER14 1EA.3208 X ---10.0 +6"-PROVIDE J-BOX OUT OF FLOOR CONNECT TO UNIT ELECTRICAL CONNECTION <br />4 <br />19 CHEFS COUNTER 2EA.120 1 X ---15EA -+34"PROVIDE DOUBLE FACED PEDISTAL DUPLEX RECEPTACLE MT'D. ON COUNTER TOP <br />(COMPONENT HARDWARE NO. R58-1020)(R71-0721) (TOTAL OF 6 DCO OUTLETS) <br />SLICER 1EA 120 1 -X 5-15P 4.0 -21 +30"PROVIDE DUPLEX RECEPTACLE <br />UNIT PROVIDED WITH 6' CORD (NEMA 5-15P) <br />1EA.208 3 24.9 -+18"HIGH TEMP WAREWASHER <br />(TANK HEAT/MOTORS)---X PROVIDE J-BOX IN WALL CONNECT TO UNIT ELECTRICAL CONNECTION23 <br />1EA.208 3 20.4 -+18"HIGH TEMP WAREWASHER <br />(BOOSTER HEATER)---X PROVIDE J-BOX IN WALL CONNECT TO UNIT ELECTRICAL CONNECTION23 <br />2EA.120 1 20 -+0"PROVIDE (2) FLUSH IN WALL MT'D DATA PLUGS (2) FLUSH IN WALL ELECTRICAL OUTLETS <br />(VERIFY W/ DISTRICT POS REQ.)--X-CASHIER STATION (DATA) AND (POWER) <br />VERIFY W/ DISTRICT FURNISHED POS UNIT29 <br />2EA.120 1 8.2 -+18"UNIT PROVIDED WITH CORD AND PLUG SET (NEMA 5-15P)-5-15PX-MILK COOLER30 PROVIDE DUPLEX RECEPTACLE <br />1EA.208 3 17.9 PROVIDE J-BOX CONNECT TO UNIT ELECTRICAL CONNECTION <br />UNIT TO BE LOCATED ON ROOF.---X +18"-31 REMOTE REFRIGERATION <br />EH2 5 -1EA.208 3 X -10.2-EXHAUST HOOD <br />(FANS CONTROLLER EXHAUST)3 +86 PROVIDE J-BOX IN WALL CONNECT TO UNIT ELECTRICAL CONNECTION <br />(REFER TO FS5.2 FOR ELECTRICAL CONNECTION) <br />2-1EA.208 3 6.1-X -EXHAUST HOOD <br />(FANS CONTROLLER SUPPLY)+86 PROVIDE J-BOX IN WALL CONNECT TO UNIT ELECTRICAL CONNECTION <br />(REFER TO FS5.2 FOR ELECTRICAL CONNECTION)EH3 5 <br />TOUCH SCREEN USER INTERFACE <br />MOUNT +48" AFF. RECESSED IN WALL ---------CONNECT TO ENERGY MANAGEMENT SYSTEM IN UTILITY CABINET AT END OF HOOD ITEM 5 <br />WITH CAT-5 CABLE (NO POWER REQUIRED AT THIS LOCATION)1EA.EH4 <br />7 E.C. TO INTERCONNECT POWER FROM HOOD CONTROL PANEL LOCATED ON WALL WITH EXHAUST DVC-1111 <br />DEMAND CONTROL <br />7 <br />E.C TO INSTALL WALL MOUNTED ENERGY MANAGEMENT CONTROL PANEL PROVIDED BY HOOD <br />MANUFACTURE FOR HOOD LIGHTS AND FAN CONTROLS20x2020x20 <br />48 21(4)54 21(4)54 21(4)48 21(4)48 21(4)E1E1JE2 <br />E1J <br />J <br />J <br />E3 <br />J <br />J <br />E5 <br />E4 <br />P E7 <br />J EH1 <br />6 <br />JE6 <br />J E8 <br />E9 <br />E11 <br />E10 <br />E12 <br />E12E12 <br />J <br />E13 <br />E14 <br />E14 <br />E15 <br />JE16 <br />J <br />E17 <br />E18 <br />E19 <br />E19 <br />JJ <br />EH2 <br />EH3 <br />HMI TOUCH SCREEN <br />+48" AFF <br />EH410'-2"J <br />E20 <br />31 <br />SHEETSOF730 Howe Avenue, Suite 450Sacramento, CA 95825Phone: 916.921.2112Fax: 916.921.2212XX <br />SHEET NO. <br />CONSULTANT <br />UPDATED <br />CADFILE <br />CHECKED <br />DRAWN <br />SCALE <br />PROJECT NO. <br />DATE <br />04/10/2020 <br />REVISIONS BY <br />19-32-050 <br />SLH <br />SLH <br />FILE NO. 39-50 APP NO. 02-118041 <br />KITCHEN RENOVATIONHOUSTON (SERNA) SCHOOLU:\Arts Projects\Greengate School\1200 Drawings\1205 Autocad Project Files\FS1.1.FB13 - March 20, 2018 - AMD - 3FOODSERVICE EQUIPMENTELECTRICAL PLANFS3.1 <br />FOODSERVICE EQUIPMENT ELECTRICAL PLAN <br />SCALE : 1/4" = 1'-0" <br />1 <br />FS3.1 <br />FOODSERVICE EQUIPMENT ELECTRICAL PARTIAL ROOF PLAN <br />SCALE : 1/4" = 1'-0" <br />2 <br />FS3.1
The URL can be used to link to this page
Your browser does not support the video tag.