Laserfiche WebLink
SAN JOAQUIN p <br /> Environmental Health Department <br /> COUNTY Linda Turkatte , REHS , Director <br /> Greatness grows here , Kasey Foley , REHS, Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellan , REHS <br /> Jeff Carruesco , REHS , RDI <br /> RECEIVED Rodney Estrada , REHS <br /> Willy Ng , REHS <br /> Muniappa Naidu , REHS <br /> February 22 , 2018 <br /> MAR 0 8 2018 <br /> Alexia Inigues <br /> Barghausen Consulting Engineers , Inc . ENVIRONNIENTAh " rALTWent by Certified Mail <br /> 18215 72nd Avenue South DEPARTMENT <br /> Kent , WA , 98032 <br /> Re : ARCO Fac . No . 7049 SR0078236 <br /> 800 East Kettleman Lane <br /> Lodi , CA . 95240 <br /> The permit application to install an underground storage tank ( UST ) system at the above address was <br /> received by the San Joaquin County Environmental Health Department ( EHD ) on October 6 , 2017 . A <br /> permit revision was received by EHD on January 17 , 2018 . In order for your application review to <br /> continue , please provide the following additional information (three copies each ) and address the <br /> following comments : <br /> 1 ) Page 3 of the Application for Underground Storage Tank Installation Permit : Indicate the <br /> Contractor' s name , phone , address , license number , hazardous waste certificate , worker' s <br /> comp number, proposed install date , and the plan reviewer's name and date . <br /> 2 ) Provide current contractor' s training certifications for installation and testing of all proposed <br /> UST equipment/components , including but not limited to : tanks , sumps , sensors , monitoring <br /> panel , leak detectors , piping , spill containment , and penetrations . <br /> 3 ) Submit a work plan for enhanced leak detection ( ELD ) testing , to be conducted by a properly <br /> licensed individual . <br /> 4 ) G . 0 . 2 . 0 — under general notes in the piping legend ( at the top ) , it is indicated that the fiberglass <br /> vapor recovery piping is 2 " inside 3" or 3" inside 4 . " Clarify which size piping to be used . <br /> 5 ) G . 0 . 2 . 0 — in the site plan , the tank 41 diagram , the turbine and fill sump legend icon is not <br /> accurate . Clarify the legend icon . Revise and resubmit. <br /> 6 ) Vacuum zone diagram , the tank #1 diagram , the turbine and fill sump legend icon is not <br /> accurate . Clarify the legend icon . Revise and resubmit . <br /> 7 ) G . 0 . 2 . 1 — <br /> a . Under ( 3 ) tank sump installation , remove 42 " diameter turbine side as the permit and <br /> plans indicates that a 48" diameter turbine side sump will be installed . Revise and <br /> resubmit . <br /> b , Under ( 9) vent piping installation , states 2 " individual single wall vent piping . Cannot be <br /> installed . Revise and resubmit . <br /> c . Under ( 10) stage II vapor recovery piping installation , states 3" single wall fiberglass <br /> vapor recovery . Cannot be installed . Revise and resubmit . <br /> 8 ) G . 0 . 2 . 2 — Under ( 13 ) dispenser installation , states single wall dispenser containment sumps . <br /> Cannot be installed . Revise and resubmit . <br /> 9 ) G . 0 . 5- <br /> a . In the pipe trench detail diagram , FRP vapor return line indicates single wall piping . <br /> Cannot be installed . Revise and resubmit . <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468 - 3420 F 209 464-0138 1 www . sjcehd . com <br />