Laserfiche WebLink
grade in contour Intervals of suffici¢nt clarity to indicate the nature and extent of the work and <br /> show in detail that it complies with the requirements of the code. The plans shall show the <br /> existing grade on adjoining properties in sufficient detail to identify how grade changes will <br /> conform to the requirements of the code. <br /> 3. A soils report is required pursuant to CBC § 1803 for foundations and CBC appendix § J104 <br /> for grading.All recommendations of the Soils Report shall be incorporated into the construction <br /> drawings. <br /> 4. The required plans must be complete at the lima of submittal for a building p¢rm it. Plans must <br /> address building design and construction, fire and life safety requirements, accessibility and <br /> show compliance with the currant California codas and San Joaquin County ordinances. A <br /> complete set of plans must include fire sprinkler plans, truss design submittals, metal building <br /> shop drawings,structural plan sand calculations,plumbing,electrical and mechanical tlrawings <br /> and anergy report. <br /> 5. For each proposed new building, provide The following information on the plans: <br /> A. Description of proposetl use <br /> B. Existing and proposetl occupancy Groups <br /> C. Type of consVuction <br /> D. Sprinklers (Yes or No) <br /> E. Number of stories <br /> F. Builtling h¢ight <br /> G. Allowable floor area <br /> H. Proposed floor arca <br /> 1. Occupant load basad on the CBC <br /> J. Occupant loatl based on the CPC <br /> 6. If high-poled combustible storage is to be usetl in a building, an automatic fire sprinkler system <br /> w(11 be required. <br /> 7. Accessible routes shall be provided per CBC § 11 B-206. At least 1 accessible route shall be <br /> provided within the site from accessible parking spaces and acc¢ssible passenger loading <br /> cones;public streets and std¢walks;and public transportation stops to the accessible building <br /> or facility entrance they serve. Whore more than 1 route fs provided, all routes must be <br /> accessible. CBC§ l l 6-206.2.1 <br /> 8. At least 1 accessible route shall connect accessible buildings, accessible facilities, accessible <br /> elements antl acc¢ssibia spaces that are on the same site. CBC§ 11 B-206.2.2 <br /> 9. At (east t accessible route shall connect accessible building or facility entrances with all <br /> accessible spaces and elements within the building or facility.Including mezzanines,which are <br /> otherwise connected by a tsirculation path. CBC § 1 t B-206.2.4 <br /> 10. Parking spaces will ba required to accommodate persons with disabilities in compliance with <br /> Chapter 11 B of the California Building Code. Nota that accessible parking spaces are required <br /> for each phase of the project.These parking spaces) shall ba located as close as possible to <br /> the primary entrance to the building. <br /> 11. Adequate sanitary facilities shall be provided for the facility, per the requirements of Chapter 4 <br /> of the 2016 California Plumbing Code. <br /> 12. Pursuant to Section 422.4 of the California Plumbing Code, toilet facilities shall be accessible <br /> to employees at all limas,should not be mora than 500 feet from where employees are regularly <br /> PA-1900197—Conditions of Approval 3 <br />