My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
3440
>
2300 - Underground Storage Tank Program
>
PR0231173
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2020 2:13:59 PM
Creation date
10/26/2020 1:09:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231173
PE
2361
FACILITY_ID
FA0006423
FACILITY_NAME
STOCKTON MOBIL 2
STREET_NUMBER
3440
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3440 E MAIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax; (209)468-3433 Web:www.s'gov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CENTRAL GAS STOCKTON 3440 E MAIN ST, STOCKTON February 22, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 205 CCR 2712(1), 2634(e) Failure to submit a current UST Response Plan and have it available onsite. <br /> An approved copy of the response plan was not available for inspection. A copy of these plans shall be accessible <br /> on site at all times. Immediately locate and retain a copy on site. <br /> This is a Class II violation. <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> A designated operator inspection was performed on October 28, 2018 and the next inspection was performed on <br /> November 28, 2018, 31 days later. The designated operator visual inspections shall be conducted within 30 days or <br /> less of the previous inspection. Ensure that all designated operator inspections are performed within the required <br /> time frames. <br /> The designated operator failed to check and note all required items on the visual inspection reports. The 10/28/18, <br /> 11/28/18, 12/28/18, and 1/27/19 inspection reports had the following issues: <br /> -Line and tank tightness testing was left blank. <br /> -Secondary containment testing was left blank with a "?" in the date section. <br /> -No overfill prevention test date was included. <br /> -No CERS ID was listed. <br /> -Section V was left blank. <br /> -The reports were unsigned by the owner/operator. <br /> During the visual inspection, the designated operator shall check that all required testing and maintenance for the <br /> UST system have been completed and shall check all required items on the report. Ensure that designated <br /> operators performing visual inspections at this facility are including all of the required information on the reports. <br /> This is a Class II violation. <br /> 210 CCR 2716(f) DO monthly reports not maintained on site for 12 months or for 36 months (after October 1, 2018). <br /> The March 2018,April 2018, and June 2018 designated operator monthly inspection reports were not found on site. <br /> Designated operator monthly inspection reports for the previous twelve months shall be retained on site. Locate <br /> and ensure that copies of the previous twelve months of designated operator monthly inspection reports are <br /> maintained on site. Submit copies to the EHD. <br /> This is a Class II violation. <br /> FA0006423 PR0231173 SCO01 02/22/2019 <br /> EHD 23-01 Rev.09/22/16 Page 6 of 8 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page