My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL PINAL
>
1325
>
2200 - Hazardous Waste Program
>
PR0543517
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2022 2:02:04 PM
Creation date
1/11/2021 2:49:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0543517
PE
2247
FACILITY_ID
FA0024706
FACILITY_NAME
METAL FINISHING SOLUTIONS - STOCKTON CA
STREET_NUMBER
1325
STREET_NAME
EL PINAL
STREET_TYPE
DR
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
1325 EL PINAL DR STE 1
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
154
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S A N J 0 A Q I I I Irl Environmental Health Department <br /> C C u N T AMENDED <br /> 8/3/2021 <br /> RCRA Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> METAL FINISHING SOLUTIONS-STOCKTON 1 1325 EL PINAL DR, STOCKTON JUly 20, 2021 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 505 CCR 66265.193 Hazardous waste tank system lacks secondary containment or leak detection. <br /> OBSERVATION: Hazardous waste tanks at this facility do not have adequate secondary containment or liquid <br /> detection equipment as required by this section. Floor degradation of the concrete treatment system secondary <br /> containment, containing the two waste corrosive tanks and the two neutralization tanks,was observed. Note:this <br /> violation was noted during the 8/31/2020 inspection and the facility responded to the violation stating that a <br /> Professional Engineer and contractor were contracted to apply adequate corrosive resistant coating by 12/30/2020. <br /> REGULATION GUIDANCE: Title 22 California Code of Regulations section 66265.193 Containment and <br /> Detection of Releases <br /> CORRECTIVE ACTION: Immediately correct any deficiencies of the secondary containment by installing a corrosive <br /> resistant coating on the floor and walls of the hazardous waste treatment area secondary containment.This coating <br /> is mentioned in the hazardous waste tank assessment document but does not appear to be currently installed. <br /> Consult with you hazardous waste tank assessment Professional Engineer to determine the correct course of <br /> action. Provide a corrective action statement and supporting documentation to the San Joaquin County <br /> Environmental Health Department(EHD)within 30 days. <br /> This is a repeat violation, Class II. <br /> 509 CCR 66265.196 Failed to immediately respond to spills and leaks from hazardous waste tank system. <br /> OBSERVATION:A hazardous waste tank system at this facility is unfit for use or has leaked or caused a spill of <br /> hazardous waste.The pump located between the two waste neutralization tanks appeared to have leaked. Liquid <br /> was observed below the pump. On 8/31/2020 SJC EHD noted this violation and determined that the liquid had a pH <br /> of 14. <br /> REGULATION GUIDANCE: Title 22 California Code of Regulations section 66265.196 Response to Leaks or Spills <br /> and Disposition of Leaking or Unfit-for-Use Tank Systems <br /> CORRECTIVE ACTION: Immediately fix the leaking pump. Provide a corrective action statement and supporting <br /> documentation to the San Joaquin County Environmental Health Department(EHD)within 30 days. <br /> This is a repeat violation, Class II. <br /> FA0024706 PR0543517 SCO01 07/20/2021 <br /> EHD 22-03 Rev.9/16/2020 Page 16 of 18 RCRA Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.