Appendix A: Alarm Codes <br /> �- <br /> Definition <br /> This Vapor Recovery alarm occurs May be caused by leaking hanging <br /> Daily Vapor when the vapors being return to hardware, blocked hoses or vapor recovery <br /> the UST are blocked. The alarm <br /> Fueling Collection or VRM Warning will occur either at the end of lines,jammed flow meter. Run Exhibit 5 <br /> Point[n] Weekly Vapor or Alarm the day or the end of the week of VR-202 to verify a blockage. Check for <br /> Collection ' leaks by viewing the vanes through the site <br /> depending on the type of vapor <br /> glass on the VFM. <br /> recovery system is installed. <br /> This vapor recovery alarm occurs Look for problems using one or more <br /> Weekly or when the UST ullage pressure of the following VR-202 procedures/ <br /> Monthly Ullage <br /> Warning exceeds the alarm threshold for tests: Dispenser Integrity Test B-3m (i.e. <br /> PressureVRM or Alarm the time period specified in the "Plumbing Tightness test), Exhibit 4, <br /> alarm. Exhibit 5, Exhibit 9(pressure sensor only) <br /> or flow rate verification per section 1.2.3. <br /> Weekly Ullage This vapor recovery alarm occurs May occur when there's an excessive leak <br /> Pressure Leak VRM Warning when the Vapor Recovery Monitor in the vapor recovery containment area. <br /> Test' or Alarm determines a leak greater than the Perform a pressure decay test per TP- <br /> allowable. 201.3. <br /> A flow meter is not connected or <br /> Channel there is an open in the wiring.This Check the connection. Measure the <br /> [n] Missing VRM Alarm will only occur for a flow meter voltage of the terminals,which should be <br /> channel that is programmed to approximately 18Vdc. <br /> have a flow meter. <br /> Channel The Vapor Recovery Monitor This may happen when a channel is <br /> [n] Error VRM Alarm does not understand the data programmed for a magnostrictive probe but <br /> transmission. has a vapor flow meter connected instead. <br /> Usually due to a bad connection or a <br /> broken wire. In some cases the sensor <br /> Pressure The pressure sensor is not may not be working. First check the <br /> Sensor Open VRM Alarm connected to the Vapor Recovery connections inside the dispenser junction <br /> Circuit Monitor. box then at the Console terminal block. <br /> Second, measure the voltage at the <br /> terminal blocks and verify the voltage. See <br /> page 17. <br /> Occurs with bad connection,TS-DIM does <br /> External TS- No communication between the not have power,TS-DIM is not working. <br /> DIM Connection VRM Alarm TS-DIM and the Console. Check the wiring between the TS-DIM and <br /> Down the Console. Check the jumper settings in <br /> the TS-DIM, see installation manual. <br /> TS-DIM Read Bad communication to the Most likely a baud rate problem. Check <br /> Data Error VRM Alarm Console. the baud rate in the Console as well as the <br /> jumper settings in the TS-DIM. <br /> Check the comm. Port settings in both the <br /> External ATG No communication or bad ATG and the Console.These comm. Port <br /> Connection VRM Alarm communication between the ATG settings should match. Make sure there <br /> Down and the Console. is a straight serial cable between the ATG <br /> and the Console. <br /> Printer Check System Warning Printer is out of paper, or the Make sure the printer has paper, and the <br /> Thermal Printer printer door is open. printer door is closed completely. <br /> Printer will resume printing and the alarm <br /> Printer Head Print head high temperature will clear after a short cool-down period. <br /> Temperature System Warning (65°C) persists for at least 2 Keep the console area cool and ventilated. <br /> minutes. If the alarm does not clear, contact FFS <br /> Technical Support. <br /> Printer Paper System Warning Indicates that paper is jammed in Carefully lift printer cover to inspect and <br /> Jam the printer remove jammed paper. <br /> II-33 <br /> CANB Approved IOM 11-INCON Vapor Recovery Monitoring(VRM)-Executive Order VR-202 <br />