My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/8/2021 4:48:00 PM
Creation date
2/22/2021 2:00:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
763
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I- . Possible Cause and Solution <br /> - <br /> [i] Module is <br /> offline, where i Occurs when a module is not If RED LED is on or Green LED is blinking <br /> Slot[n] is the module System Alarm communicating with the controller. try cycling power. <br /> number <br /> [i] Module <br /> number Occurs when the number of Check the setup at System <br /> mismatch, System Alarm modules does not match the Configuration»Modules Expected to see <br /> where i is the programmed number of modules. if the correct numbers are programmed. <br /> module number <br /> Check to see if a particular module has <br /> System Bus The communication bus is not a red Error LED. If so try to trouble shoot <br /> Error System Alarm working properly. the bad module.Also try removing the bad <br /> module and see if the alarm goes away. <br /> Wrong ID Number <br /> Remote DTU is A remote DTU is not Dispenser Powered Off <br /> TS-DTUn Offline System Alarm communicating to the console Not installed correctly <br /> DTU. Not on same phase voltage as console <br /> DTU <br /> Console Bad bus connection <br /> DTU number System Alarm The console DTU is not Not powered <br /> mismatch communicating with the console. <br /> DTU FFS System Alarm Two networks have the same Change Network ID <br /> Interference Network ID <br /> OWC-3ON <br /> Franklin Fueling Systems <br /> www.franklinfueling.com <br /> 3760 Marsh Road•Madison,WI 53718,U.S.A. <br /> Tel:+1 608 838 8786•Fax:+1 608 838 6433 <br /> Tel:USA&Canada 1 800 225 9787•Tel:Mexico 001 800 738 7610 <br /> Franklin Fueling Systems GmbH <br /> Rudolf-Diesel-Strasse 20•54516 Wittlich,GERMANY <br /> ©2009 FFS 000-2058 Rev. E Tel:+49-6571-105-380•Fax:+49-6571-105-510 <br /> II-34 <br /> CARB Approved IOM 11-INCON Vapor Recovery Monitoring(VRM)-Executive Order VR-202 <br />
The URL can be used to link to this page