N LO <br /> I— <br /> Side View 208v 10 120v 10 U <br /> F I <br /> W/GROUND . W <br /> W/GR❑UND H <br /> Rigid LWIRE <br /> 208v 30 � _ <br /> Inside wall--w- ductworkI Uutside wall FUSED DISC BY <br /> W/GR❑UND I I i <br /> ELECTRICAL <br /> WINDOW SWITCH - GR1 5065 REED SWITCH FUSED DISC BY CONTRACTOR � J I I = <br /> WIRE Flexible or <br /> iv rigid duct ] W/ MAGNETIC CONTACT, SILICON TO WINDOW, ELECTRICAL TDR-1 - IDEC GT3A-1-AC24V I <br /> 120v 10 Unit U <br /> CONTRACTOR <br /> 1 MOUNT W/ VERTICAL JAMB OF WINDOW. 208V 10 RR=1 - IDE( RY4S-U-L-AC24V scHPFc- 24V UNIT I I <br /> W/GR❑UND Air discharg 1 W/GROUND XFRMR <br /> FUSED DISC BYU WIRE • d" Tnin.from front of case-Unit outlet MAGNETIC CONTACT MC-25 WIRE LINE Rc RH YI Y2 W1 G <br /> ELECTRICAL Wall plenum `A"" <br /> installed through FRONT of case. <br /> CONTRACTOR • 5" min.from front of case-Unit ExteriorlDutside PTHC- UNIT 24V I <br /> C) WINDOW INNCOM <br /> XFRMR <br /> LINE EC❑N L❑GIC installed through 510E of case_ SWITCH ®E528 RC Y1 RV O G RED INC ARCHITECTS <br /> • 3" min.from two sides of case. <br /> RTU- BOARD Wail plenum AIR PRODUCTS SL 1217 J STREET, MODESTO, CA 95354 <br /> >_ UNIT Plenum <br /> divider c SEQUENCE OF OPERATION 2000 PH❑TELECTRIC 209.522.8900 <br /> XFRMR on 1cutout SMOKE DETECTOR <br /> o RC RH G Yl Y2 Wl W2 C 24 C Aperess panel with�� - <br /> 32114"H WHEN WINDOW OPENS, <br /> O x 20"W TDR-1 SHALL MAKE & NCIII, tot <br /> CJ ret0rn air grille Filter bracket DELAY NO CONTACT FOR <br /> Q Option 2 RR=1 NC R 15 MIN. AFTER 15 SHALL ENERGIZE MIN. <br /> AND DSD. SD <br /> J DSD, SD RPRODUCTS <br /> eturn air grille Drain fitting 314" NO KILL HEAT & COMPRESSOR. RC RH Y1 Y2 W1 G MS-RH/KAGRN AT O �S� FjL <br /> LU ON AL <br /> V) PH❑TELECTRIC SMOKE AIR PRODUCTS SL 0 Bottom of ease approx.2' RED LED O R <br /> P RC RH Yl Wl ❑ G C HORN/STROBE O O <br /> p AUTOMATED DEMAND RESPONSE <br /> T <br /> DETECTOR ctrl above bottom of plenum TDR-1 MD HONEYWELL SERIES 8000 WITH RESET O O i� <br /> A Secure latfarni p <br /> RC RH G Yl Y2 Wl W2 C NC y�r� MOUNT IN OSA FUNCTION <br /> to the floor INTAKE AT _ f <br /> z Wall plenum HONEYWELL RLV4300A THERMOSTAT <br /> d r� P = THERMOSTAT POWER r REN. 6-30-20 <br /> HONEYWELL VISI❑NPR❑ 8000 WITH � �-- M2975 �- <br /> AUTOMATED DEMAND RESPONSE FIREX REMOTE + 8' min. Platform:23-114"x 23-114"square S C H P E C- THERMOSTAT 1 U) <br /> o TEST SWITCH for drain Min. load capacity: 175 lbs. 7 DETAIL �� �� HA GQ OQ� <br /> I,, FUNCTI❑N SERIES Y AND W AND LED'S GRN LED O access G UES T P TAC- T-STA T <br /> v TERMINALS T❑ MATCH UNITS RED LED O DETAIL TYPICAL FOR EACH GUEST ROOM (95 TOTAL) M O.1 IVIUJI G 1 �F C <br /> o <br /> HORN/STROBE O O <br /> RESET O Bottom of case approx. 2" ❑ (ELECTRIC HEAT) <br /> Q AIR PRODUCTS B �� above bottom of plenum RV (REVERSING VALVE) 3/4' CONDUIT T <br /> N MS-RH/KA/P/AT 1 � + Platform ---LINE VOLTAGE WIRING BY EC LINE VOLTAGE WIRING BY MC MOTORIZED DAMPER MD-1 <br /> CMD) <br /> AW Wil LOW VOLTAGE WIRING BY MC <br /> NOTE APPLIES TO ALL DETAILS <br /> N THERMOSTAT (7�6 j INNCOM E528 BY ELECTRICAL CONTRACTOR, WIRED AND INSTALLED BY 2-PAIR 18 GA WIRE <br /> X � HVAC CONTRACTOR IN UNIT IN AN ACCESSIBLE LOCATION. - RUN IN 3/4" Fes- CONSULTANT: <br /> CONDUIT T❑ HPFC- EQUIPM NT IN <br /> DETAIL M O. 1 HP-/OHP GENERAL ❑❑ <br /> Field supplied 208V, 240V SYSTEM ❑ <br /> z A Minimum recommended access door width:30' Outside wall outer flashing <br /> � 8 <br /> 9 (42' FOR 480V SYSTEM) OUTDOOR GANG U ❑ ❑ <br /> V) B Minimum recommended access door height:50' CL BOX - RUN INVERTED SUCTI❑N TRAP - STUB CONDUIT 6' Z � ❑ <br /> DUCT SUPPORT T-STAT WIRE IN SECOND FLOOR UNITS ONLY ABOVE MEZZANINE 0 ❑ t <br /> w WYE/ELB❑W/SAMCNA SEAL TIGHT -1 n <br /> w LOW LOSS 'T' 'A' ❑R 'B' -LIQUID LINE WITH LIQUID 3/4' CONDUIT IN WAL (9 I ❑ <br /> = BELOW CONDUIT TO LINE DRIER AND MOISTURE Z W N <br /> FITTING 00 00 <br /> N ELECTRICAL PANEL OR HP-/❑HP- INDICATING SIGHT GLASS AT N C? Q <br /> rn UNIT DISCONNECT DEDICATED CLEAR C❑NDENSING UNIT T W <br /> " MOUNT T-STAT 48' AFF AWAY FROM co W 1 L71 a CO <br /> CR-1 RA PLENUM 3 6 UNOBSTRUCTED WORKING SPACE HEAT PRODUCING DEVICES, CD Z_ <br /> 4-#12GA CEILING WIRES TO COORDINATE L❑CATI❑N WITH OWNER N () ❑ <br /> IN FRONT ❑F PANEL, <br /> SUPPORT 1' THICK DUCT BOARD l� m (7 � � � O O ❑ <br /> ELBOW AND REGISTER. ATTACH FLOOR/ROOF TO STRUCTURAL HEET METAL WALL FLASHING IN O N N <br /> VD-- 5, MAX FLEX MEMBER ABOVE PER NEC110-16 OHP- Z -I <br /> REGISTER T❑ T-BAR W/(2) WALL, D❑ NOT CORE BLOCK - SEAL <br /> #7x1/2' S/M SCREWS THRU & 384-4, VERIFY ALL WITH FOAM AFTER INSTALLING W N J <br /> OUTLET FLANGE TO GRID RUNNER POSSIBLE CONFLICTS WITH D_ LL <br /> CS- 4A.CS-1. DS-1 VD FURNISH AT ALL SUPPLY ON ❑PP❑SITE CORNER 15" 15' OTHER TRADES PRI❑R TO REFRIGERANT LINES N <br /> - TITUS ❑R REGISTERS IN WYE OR TAP, <br /> ROUGHING IN THE PANEL BOARD IQUID LINE WITH LIQUID LINE DRIER � <br /> 7 <br /> EQUAL, WHITE DAMPER SHALL HAVE NECK SIZE OR DISCONNECT, AND SIGHT /MOISTURE INDICATING GLASS (7 <br /> FINISH, NO OBD, LOCKING QUADRANT ON 1" AT C❑NDENSING UNIT <br /> SIZE AS INDICATED STANDOFF, 3/8'0 DIAMETER <br /> ON FLOOR PLANS SHAFTS. »»»»»»»» <br /> o ELECTRICAL PANEL/DISCONNECT 8 HP-/OHP, FC-/HPFC- REFRIGERATI❑N/TSTAT PIPING 2 W <br /> PLYW❑❑D/SKIP M Q 11 DETAIL M Q 1 <br /> SHEETING ROOF � DETAIL <br /> ATTACH TO (E) JOISTS <br /> WITH 1-#10x1-1/2' 2'x24 GA GI DUCT SUPPORT STRAP <br /> 2x2 FASTAP SCREW, WITHIN 2' OF REGISTER - MIN FLEX 1-1/2' DUCT LINER <br /> -ATTACH TO J❑IST DUCT LENGTH IS PLA S❑ THAT ALL WALL FRAMING PER LISTING TYP SA AND RA <br /> W/2-1/4'Ox2' LAGS - DUCTS SHALL DISPLAY THE DUCT PLENUMS R=8.2 <br /> EMBED 1-1/2' MIN IZE AND INSULATION VALUE AND <br /> MAX LENGTH IS 10' FOR ❑SHPD, 5'0' TTACH ANGLES TO DUCT PER CSFM LISTING. REFRIGERANT LINES - <br /> DUCT STRAP ���� <br /> FOR ALL OTHERS, ALL ELBOW AIR GAP PER INSTALLATION INSTRUCTIONS SIZE PER I <br /> DOUBLE NUTTED ALL PER CMCJ- RADIUS'S TO BE 1,5 DUCT DIAMETER, REAKAWAY CONNECTION MANUFACTURER'S <br /> THREAD ROD WITH FLEX DUCT TURNS TO BE 2,0 DUCT OPERATOR W/FUSE LINK RECOMMENDATIONS <br /> SQ 1-�'xl-b'x6' DIAMETER ACCESS DOOR <br /> WASHER T❑ SUPPORT SMOKE DETECTOR 0 <br /> STRAP , AT CEILING SYSTEM DETECTOR IN SPACE 3/4' C❑ND DRAIN <br /> ❑R LINE - 2' MIN TRAP <br /> 1-h'x24 GA <br /> BELLY BAND AIR OUTLET - WT<10# FLEX CONNECTOR <br /> AROUND PIPE GA SLACK WIOR RE ON12 WHEN UNIT IS ON ISOLATORS n <br /> A DUCT SUPPORT ❑PP❑SITE CORNERS \ B by H I LTO N" <br /> NOTE <br /> PLYW❑❑D/SKIP SECURE CEILING OUTLET TO S,A,T, MOTORIZED 24V DAMPER, SR <br /> SHEETING R❑OF CEILING GRID WITH (2) #10x1/2' S/M - INTERLOCK AN <br /> 2x2x " ANGLE SCREWS THRU OUTLET FLANGE TO FC-1 <br /> ATTACHTO GRID RUNNER AND AT DIAG❑NAL RETURN DUCT <br /> J❑IST/TRUSS OSA DUCT VD Q <br /> ____W/ a'xl-1/2' CORNERS INSTALL (2) #12 GA. SLACK <br /> LAG BOLT - WIRES ATTACHED TO STRUCTURE Z <br /> ABOVE USING CLOSED LOOP EYEBOLTS, NGLES T❑ BE INSTALLED PER CSFM LISTING <br /> EMBED 1' MIN WIRE AND SCREWS ARE REQUIRED ON 50% UNIT O <br /> ALL REGISTERS, FILTER LL <br /> 3/8'x2' LAG BOLT� DOUBLE NUTTED ALL MAX FPMVEL J <br /> EMBED 1'INT❑ THREAD ROD WITH SQ Q <br /> JOIST/TRUSS 1- 'xl- 'x ' WASHER Q L_ -1 3/4' OVERFLOW ON UNITS U <br /> ABOVE <br /> 1-�'xl- 'x18 GA T❑ SUPPORT STRAP W A L L E I R E S M❑K E D A M P E R 7 f CEILINGS INSTALLED <br /> DS-DISCHARGE IN <br /> SEISMIC BRACE 1- 'x24 GA BELLY T-B A R REGISTER 1 3 DETAIL M O Z SEE 'k_ - ANSEESPL MB NG LOCATION <br /> -LOCATE EVERY 40' <br /> AND AT CHANGES IN BAND AROUND PIPE DRAWINGS <br /> DIRECTI❑N OF PIPE - DUCT IS EXPOSED DETAIL M 0 1 24 GA GI AUX. DRAIN PAN - EXTEND <br /> 26 GA GI 1. FIRE SMOKE DAMPER SHALL BE UL LISTED AND CALIFORNIA STATE FIRE MARSHAL UNDER C❑IL AND FURANCE <br /> LATERAL BRACE 80' WEEP LISTEPARTITION USKIN SFD60,PENE RATED,WITH FIRE INSTALL PER CSFMON RATING TO MATCH LISTING #3225-24502 E C-/HPFC- INSTALLATION D E T A I L S 3 <br /> ❑C AND AT CHANGE SCREED 2. FIRE SMOKE DAMPER SHALL DETAIL FOR REFERENCE ONLY, M <br /> 3. FIRE SMOKE DAMPER SHALL BE STATE FIRE MARSHALL APPROVED AND DETAIL <br /> LATERAL BRACE OF DIRECTION STUCCO COUNTER INSTALLED STRICTLY PER THE MANUFACTURER'S PRINTED INSTRUCTI❑NS. <br /> 40' ❑C AND AT FLASHING U DUCT - 4. MANUFACTURER'S INSTALLATION INSTRUCTIONS SHALL BE MADE <br /> CHANGE ❑F SEAL E DUCT USING AVAILABLE TO THE INSPECTING AUTHORITIES, DAMPER TO BE RUSKIN FSD 60 <br /> DIRECTION SIKA FLEX AND #6 SM 5. DAMPER SHALL BE POWER OPENED, FAIL CLOSE. OPERATORS SHALL BE SPRING RETURN, <br /> SCREWS 4' ❑C TO FORM A OPERATORS SHALL BE UL LISTED FOR FIRE DAMPERS AND BEAR UL LABEL. 4-12 GA CEILING WIRES 0 La <br /> WATAERTIGHT SEAL 6. SMOKE DETECTORS SHALL ELECTRICALLY AND MECHANICALLY LOCK DAMPER IN A CLOSED POSITION STRAPPED AROUND WHEN DUCT TEMPERATURE EXCEEDS 165E WHILE ALLOWING REMOTE OVERIDE, FRAMING AND TWISTED 3 FIRE DAMPER <br /> C/j i i 7. SMOKE DETECTOR, WIRING, CONDUIT, AND LABOR REQUIRED TO CONNECT THE DAMPERS WITH THE <br /> B SEISMIC A N C H❑RAGE DETAIL N❑LL PRODUCTS FIRE ALARM SYSTEM OR OTHER SYSTEMS SHALL BE FURNISHED BY OTHER TRADES AS DESCRIBED ON TIMES MINIMUM AROUND SHEET METAL DUCT <br /> v 26GA SLEEVE FOR LOUVER <br /> SELF FLASHING THE DRAWINGS AND IN THE SPECIFICATI❑NS. ITS4 EXTENSI❑N <br /> DUCT D U P P❑R T S 1 7 LOUVER WITH FRAME - SEAL 7. POWER, SMOKE DETECTOR - BY FAC, OPERATOR - 120V/10 DAMPER TO BE INSTALLED REFRACTORY <br /> 0 DETAIL TIGHEXTETOR SIKAFLEX NG WATER NO MOR FINIS ED THAN "CEO❑NE <br /> CERAMIC BLANKET W <br /> M 0. 1 LAG RING TO 2x BLOCKING H <br /> 26 GA GI WEE EMBED' LAGS 12' ❑C FURNISHEDFUSED BY EMBEDDED 2" 120V, 1 P <br /> SCREED 1 ELECTRICAL I I <br /> WALL - SEE DSD, SD CONTRACTOR (EC). <br /> ARCH DRAWINGS UNIT 208V, 1 PH <br /> W RTU- AMPERAGE SPECIFIED FRAMING MEMBER CONS CEILING <br /> F❑UNDATI❑N � +FIREX 0551H NON-FUSED ON ELECTRICAL C❑NSTRUCTI❑N <br /> ATTACH 6' MINERAL WOOL WALL DISCONNECT. <br /> ,� PH❑TELECTRIC SMOKE DRAWINGS. STEEL T-BAR J <br /> O SOUND BLANKETS TO BOTTOM � <br /> DETECTOR AMPERAGE REGISTER <br /> C OF UNIT TO DEADEN SOUND NC SPECIFIED } 208V, 3PH/ <br /> p GASKET - USE MANUFACTURER'S ON DATA TABLE. -7 _F F_ CEILING EIRE DAMPER W <br /> N SUPPLIED WITH CURB ❑A L-1 MOUNTING 1 4 FIREX REMOTE Ll UNIT 4 <br /> MANUFACTURER'S ROOF CURB NO SCALE TEST SWITCH CONTROL DETAIL <br /> 14' MIN HT, 18 MIN C❑NSTRUCTI❑N M Q, 1 AND LED'S CP- RELAY c L TRANSF❑ MER T <br /> O GRN LED a 0 GWIY O O 1. FIRE DAMPER SHALL BE UL LISTED AND CALIFORNIA STATE FIRE <br /> Q 12 GA ANGLE CLIP - ATTACH O RED LED I <br /> TO CURB W/3#10x1' SM SCREWS R OHP- MARSHAL LISTED, RUSKIN CFD2- WITH FIRE PR❑TECTI❑N RATING <br /> O O <br /> HORN/STROBE <br /> TO UNIT W/#10x1' SM SCREWS O RESET T❑ MATCH PARTITION PENETRATED, O <br /> �- CLIP TO BE 6'MIN LONG. 2 EA 2. FIRE DAMPER SHALL DETAIL FOR REFERENCE ONLY, LL_ <br /> +� <br /> LONG SIDE OF UNIT AT CORNERS WALL FRAMING PER M-1, MD OSA DAMPER 3, FIRE DAMPER SHALL BE STATE FIRE MARSHALL APPR❑VED AND <br /> 0 26 GA GI LISTING GREENHECK ROUND DAMPER, INSTALLED STRICTLY PER THE MANUFACTURER'S PRINTED 0 <br /> � C❑UNTERFLASHING p AIR GAP PER 1/2" SHAFT WITH BLADE - INSTRUCTI❑NS. C.) <br /> +_� ATTACH ANGLES TO 4. MANUFACTURER'S INSTALLATION INSTRUCTIONS SHALL BE MADE Z <br /> FILL CURB VOID SPACE INSTALLATION SEALS AND BELIMO NM SERIES _ � � <br /> W/ RIGID INSULATI❑N INSTRUCTI❑NS DUCT PER CSFM SPRING RETURN CLOSED AVAILABLE T❑ THE INSPECTING AUTHORITIES, DAMPER T❑ BE <br /> -p AND UNDER UNIT WITH LISTING, DAMPER MOTOR SIZED TO RUSKIN CFD25, CSFM# 32225-2451015, Q <br /> ROCK WOOL BATT MATCH DAMPER AREA. LRM a ri e wiwzD i <br /> INSULATION BREAKAWAY • • Q <br /> O C❑NNECTI❑N FLEX DUCT T❑ MAIN RUN T❑ BE <br /> 0 FINISH R❑❑FING - ROLL FUSE LINK HONEYWELL SERIES 8000 VISI❑N PRO THERMOSTAT <br /> Z <br /> UP CURB AND ATTACH T WITH AUTOMATED DEMAND RESPONSE FUNCTI❑N MIN 3'2" LENGTH S❑ THAT THE O <br /> O NAILER SERIES Y AND W TERMINALS T❑ MATCH UNITS <br /> HOENYWELL DUCT SIZE AND INSULATI❑N <br /> 3/8'Ox3-1/2' LAG BOLT - EMBED ACCESS DOOR JADE VALUE IS SHOWN ON ALL DUCTS <br /> ECONOMIZER U <br /> N 3' MIN, PLACE 48'❑C ' 18 GA. SOLID CU 4 PAIR T-STAT WIRE - RUN IN AND MAX LENGTH T❑ BE 10'0" FOR <br /> c> CONTROLLER ❑SHPD AND 5'0' FOR ALL OTHERS, <br /> SEE STRUCT DWGS CONDUIT FROM F- TO CU-, PROVIDE 4x4x2" � O <br /> F❑R TRUSSES J-BOXES EVERY 100' AND EVERY 360' CHANGE IN 12' GI DUCT EXTENSI❑N F- <br /> 0 DIRECTION PER NEC REQUIREMENTS ABOVE CEILING (/) _ <br /> Q 4x BLOCKING BY GC INSULATI❑N, FLEX Z <br /> SEAL AIRTIGHT ❑ DUCT T❑ MAIN RUN O Q <br /> SHEET METAL DUCT HPFC-1,2,3,4,5 OHP-1,2,3,4,5 CONTROL WIRING 1 0 U J <br /> W/1" 6,2R LINER ', <br /> Q DETAIL n q 0 1 24 GAUGE GI REGISTER <br /> CAN <br /> RTU - CURB MOUNT 1 B ?:. ANGLES T❑ BE 120V, 1 PH IVI SCREW CAN TO <br /> BLOCKING - 4 TOTAL <br /> DETAIL INSTALLED PER CSFM REVISIONS: <br /> LISTING DISCONNECT, <br /> UNIT NON-FUSED I I <br /> 208V, 1 PH 2Q HILTON 10/18/2018 <br /> AMPERAGE <br /> FIXED WINDOW T- <br /> T SPECIFIED [ �- <br /> ON DATA TABLE. <br /> UNIT FUSED DISCONNECT <br /> �+ — L1 HPFC- FURNISHED BY <br /> OPERABLE WINDOW UMT L_�_ LREGISTER <br /> PER CMC 504,5, EXHAUST OUTLETS M 1 5 r _� ELECTRICAL CONTRACTOR _ SEE PLAN <br /> a SHALL TERMINATE NO LESS THAN 3 DETAIL SPECIFIED ON <br /> -t3 FEET FROM PROPERTY LINE AND 3 MD- C L TRNASFORMER L T—I J (EC). AMPERAGE <br /> FOR SIZES - PROVIDE <br /> M 0. 1 R O W2 G W Y1 ELECTRICAL DRAWINGS, 1/2' SOUND LINER IN <br /> FEET FROM OPENINGS INT❑ BUILDING, REGISTER CAN <br /> TYPICAL FOR ALL EA DUCT <br /> C_ TERMINATIONS TO BUILDING EXTERIOR, 1. FIRE DAMPER SHALL BE UL LISTED AND CALIFORNIA STATE FIRE MARSHAL <br /> LISTED, RUSKIN IBD2, WITH FIRE PR❑TECTI❑N RATING TO MATCH CEILING REG DETAIL <br /> PARTITI❑N PENETRATED, INSTALL PER CSFM LISTING #3225-245102 OHP- <br /> TODUCT TERMINATION 2. FIRE DAMPER DETAIL SHALL BE FOR REFERENCE ONLY, OSA DAMPER 5 <br /> T❑ BUILDING EXTERIOR 3. FIRE DAMPER SHALL BE STATE FIRE MARSHALL APPROVED AND DETAIL <br /> Q> INSTALLED STRICTLY PER THE MANUFACTURER'S PRINTED INSTRUCTI❑NS, KZE1 <br /> C_ 4. MANUFACTURER'S INSTALLATI❑N INSTRUCTI❑NS SHALL BE MADE LOW VOLTAGE <br /> T-0"MIN AVAILABLE TO THE INSPECTING AUTH❑RITIES, WIRING 18 GA. 4 PAIR T-STAT <br /> 5. DAMPER OPERATORS SHALL BE SPRING RETURN WHEN INSTALLED WIRE - RUN IN REF-BASE <br /> Q 18 GA. CONDUIT FROM F-1 TO <br /> OPERABLE W I N D ❑ W S IN A HORIZONTAL POSITION ACCU-, PROVIDE 4x4x2" # <br /> q 4 PAIR GASKET - 1/4' NEOPRENE RED PROJECT 18050 <br /> 1F#RO2G w Y1 T-STAT WIRE -BOXES EVERY 100' AND 20 GA CURB W/3/4' <br /> HILTON 18-428ND <br /> o DETAIL M 0. 1 HONEYWELL VISION PRO EVERY 360 CHANGE IN # <br /> DIRECTION PER NEC PLYWOOD NAILER <br /> FURNACE/HEAT PUMP REQUIREMENTS <br /> 10' MIN HT PLANNING # SPR-18-102 <br /> PROGRAMMABLE <br /> p 26GA GI (E)EXTERIOR THERMOSTAT ATTACH REF-TO CURB W/ 6'xl' PERMIT # - <br /> DUCT WALL LAG SCREWS - 1-EACH SIDE <br /> A HP-1,2, HPFC-1A,1B,1 C,2A,2B C❑NTS❑L WIRING 1 1 26 GA GI APN # 196-270-23 <br /> a> C❑UNTERFLASHING <br /> Q- 26GA GI DETAIL <br /> DUCT FILL V❑ID SPACE W/ DATE: 11.12.18 <br /> Q- FIRE CAULK WHERE RIGID INSULATION <br /> -a DUCT PENETRATES FINISH R❑❑FING - ROLL <br /> DRAWN: N R <br /> N SHEET ROCK UP CURB AND ATTACH TO <br /> (N) BLOCKING w/ NAILER CHECKED: GD <br /> 5/8' TYPE 'X' SHEET <br /> OC TOE NAIL SEAL OPENING W/ CANT STRIP BY ROOFER <br /> Q <br /> TO JOIST SEE DETAIL BASE 1/4'Ox2-1/2' LAG BOLT - EMBED <br /> 16/903 HILTI INTUMESCENT <br /> FIRE CAULK AROUND <br /> DUCT 1/2' DIAM. <br /> OFFSET DUCTING SPACE INTO <br /> 2" MIN, PLACE 48"❑C SHEET TITLE: <br /> FURNISH W/ 6x FIRE CAULK WHERE B HILTI HKBII SEE ARCH DWGS <br /> CEILING FIRE DAMPER, DUCT SHEETPENETRR❑CK B❑TT❑MATES TYP. (❑F 4❑xRBLOCKING BY GC <br /> P/❑HP 3/8' DIAM, HILTI STRUCTURE <br /> KB-III EMBED <br /> V) TYPICAL FOR EACH GEF, UNIT 2-1/2' MIN, Cl) SEE ARCG DWGS FOR FIRE PROTECTION <br /> 2x FURRING STRIP //-26GA GI PIPE EACH CORNER (2) HANGERS <br /> TOTAL SHEET METAL DUCT SEAL AIRTIGHT DETAILS <br /> (2)LAYERS J❑IST -SEE DWGS �4' THICK W/Y2'2,0 PCF DENSITY <br /> 5/8' TYPE 'X' FOR SIZES ° °' HOUSEKEEPING SOUND LINER <br /> Q> SHEET ROCK 24 GA GI TIGHT N PAD-BY GC <br /> � SEE DETAIL FITTING ESCUTCHEON BASE MATERIAL <br /> p 16/903 ______ <br /> HEET R❑CK 5/8' <br /> $,SEEP 6/903 FILL ANNULAR SPACE W/ HP/OHP M❑UNTING (�l2 ROOF EXHAUST E A N CURB 6 <br /> CE E—1 AND FRAMING SECTION HILTI INTUMESCENT DEraL M O. 1 <br /> DETAILS T❑ HOOD FIRE CAULK AROUND DUCT DETAIL <br /> 2 SEE DETAIL 16/903 FOR CHASE <br /> C METAL FRAMING STRIPS <br /> SECTIONA TO SUPPORT SHEET ROCK SECTION B <br /> SHEET NO.: <br /> CEF- M❑UNTING, FRAMING AND FIRECAULKING W/ CED <br /> (�20 <br /> DETAIL M�- i <br /> M0 . 1 <br />